DS1220AD-100IND Maxim Integrated Products, DS1220AD-100IND Datasheet
DS1220AD-100IND
Specifications of DS1220AD-100IND
Available stocks
Related parts for DS1220AD-100IND
DS1220AD-100IND Summary of contents
Page 1
... Optional industrial temperature range of -40°C to +85°C, designated IND DESCRIPTION The DS1220AB and DS1220AD 16k Nonvolatile SRAMs are 16,384-bit, fully static, nonvolatile SRAMs organized as 2048 words by 8 bits. Each NV SRAM has a self-contained lithium energy source and control circuitry which constantly monitors V occurs, the lithium energy source is automatically switched on and write protection is unconditionally enabled to prevent data corruption ...
Page 2
... OE WRITE MODE The DS1220AB and DS1220AD execute a write cycle whenever the WE and CE signals are active (low) after address inputs are stable. The latter occurring falling edge will determine the start of the write cycle. The write cycle is terminated by the earlier rising edge All address inputs must be kept valid throughout the write cycle ...
Page 3
... CAPACITANCE PARAMETER Input Capacitance Input/Output Capacitance SYMBOL MIN TYP MAX UNITS V 4.75 5.0 5. 4.50 5 0.0 +0 ± 5% for DS1220AB ± 10% for DS1220AD SYMBOL MIN TYP MAX UNITS -1.0 I +1.0 IL -1 5.0 10.0 CCS1 I 3.0 5.0 CCS2 I 75 ...
Page 4
... Output Hold from Address Change Write Cycle Time Write Pulse Width Address Setup Time Write Recovery Time Output High from WE Output Active from WE Data Setup Time Data Hold Time = 5.0V ± 5% for DS1220AB 5.0V ± 10% for DS1220AD DS1220AB-100 SYMBOL DS1220AD-100 MIN MAX t 100 RC t ...
Page 5
READ CYCLE SEE NOTE 1 WRITE CYCLE 1 SEE NOTES AND 12 WRITE CYCLE 2 SEE NOTES AND DS1220AB/AD ...
Page 6
POWER-DOWN/POWER-UP CONDITION SEE NOTE 11 POWER-DOWN/POWER-UP TIMING PARAMETER V Fail Detect to and slew from slew from Valid to and Inactive ...
Page 7
... ORDERING INFORMATION PART DS1220AB-100+ DS1220AB-100IND+ DS1220AD-100+ DS1220AD-100IND+ + Denotes a lead(Pb)-free/RoHS-compliant package. PACKAGE INFORMATION For the latest package outline information and land patterns www.maxim-ic.com/packages. that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status ...
Page 8
REVISION HISTORY REVISION DATE Added package information table; removed the DIP module package 121907 drawing and dimension table Updated the storage and soldering temperature information in the Absolute Maximum Ratings section, removed the unused AC timing 10/10 specs in the ...