AT49BV162A-70TI Atmel, AT49BV162A-70TI Datasheet - Page 8

IC FLASH 16MBIT 70NS 48TSOP

AT49BV162A-70TI

Manufacturer Part Number
AT49BV162A-70TI
Description
IC FLASH 16MBIT 70NS 48TSOP
Manufacturer
Atmel
Datasheet

Specifications of AT49BV162A-70TI

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
16M (2M x 8 or 1M x 16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.65 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT49BV162A-70TI
Manufacturer:
ATMEL
Quantity:
5 530
4.9
4.10
4.11
4.12
8
Erase Suspend/Erase Resume
Program Suspend/Program Resume
Product Identification
128-bit Protection Register
AT49BV162/163A(T)
The Erase Suspend command allows the system to interrupt a sector or chip erase operation
and then program or read data from a different sector within the memory. After the Erase Sus-
pend command is given, the device requires a maximum time of 15 µs to suspend the erase
operation. After the erase operation has been suspended, the system can then read data or pro-
gram data to any other sector within the device. An address is not required during the Erase
Suspend command. During a sector erase suspend, another sector cannot be erased. To
resume the sector erase operation, the system must write the Erase Resume command. The
Erase Resume command is a one-bus cycle command. The device also supports an erase sus-
pend during a complete chip erase. While the chip erase is suspended, the user can read from
any sector within the memory that is protected. The command sequence for a chip erase sus-
pend and a sector erase suspend are the same.
The Program Suspend command allows the system to interrupt a programming operation and
then read data from a different byte/word within the memory. After the Program Suspend com-
mand is given, the device requires a maximum of 20 µs to suspend the programming operation.
After the programming operation has been suspended, the system can then read data from any
other byte/word that is not contained in the sector in which the programming operation was sus-
pended. An address is not required during the program suspend operation. To resume the
programming operation, the system must write the Program Resume command. The program
suspend and resume are one-bus cycle commands. The command sequence for the erase sus-
pend and program suspend are the same, and the command sequence for the erase resume
and program resume are the same.
The product identification mode identifies the device and manufacturer as Atmel. It is accessed
using a software operation.
For details, see
sections on
The AT49BV162A(T)/163A(T) contains a 128-bit register that can be used for security purposes
in system design. The protection register is divided into two 64-bit blocks. The two blocks are
designated as block A and block B. The data in block A is non-changeable and is programmed
at the factory with a unique number. The data in block B is programmed by the user and can be
locked out such that data in the block cannot be reprogrammed. To program block B in the pro-
tection register, the four-bus cycle Program Protection Register command must be used as
shown in the
Lock Protection Register command must be used as shown in the
Data bit D1 must be zero during the fourth bus cycle. All other data bits during the fourth bus
cycle are don’t cares. To determine whether block B is locked out, the Product ID Entry com-
mand is given followed by a read operation from address 80H. If data bit D1 is zero, block B is
locked. If data bit D1 is one, block B can be reprogrammed. Please see the
Addressing Table” on page 14
protection register, the Product ID Entry command is given followed by a normal read operation
from an address within the protection register. After determining whether block B is protected or
page
“Command Definition Table” on page
“Operating Modes” on page 17
23.
for the address locations in the protection register. To read the
or “Software Product Identification Entry/Exit”
13. To lock out block B, the four-bus cycle
“Command Definition Table”
“Protection Register
3349H–FLASH–3/05
.