DS2786G+ Maxim Integrated Products, DS2786G+ Datasheet - Page 7

IC FUEL GAUGE OCV 10-TDFN

DS2786G+

Manufacturer Part Number
DS2786G+
Description
IC FUEL GAUGE OCV 10-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2786G+

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion), Lithium-Polymer (Li-Pol)
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-TDFN Exposed Pad
Operating Supply Voltage
2.5 V to 5.5 V
Supply Current
50 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
No
Mounting Style
SMD/SMT
Temperature Monitoring
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
POWER MODES
The DS2786 operates in one of two power modes: Active and Sleep. While in Active mode, the DS2786 operates
as a high-precision battery monitor with temperature, voltage, auxiliary inputs, current, and accumulated current
measurements acquired continuously and the resulting values updated in the Measurement Registers. In Sleep
mode, the DS2786 operates in a low-power mode with no measurement activity. Read and write access is allowed
to all registers in either mode.
The DS2786 operating mode transitions from Sleep to Active when:
The DS2786 operating mode transitions from Active to Sleep when:
CAUTION: If SMOD = 1, a pullup resistor is required on SCL and SDA in order to ensure that the DS2786
transitions from Sleep to Active mode when the battery is charged. If the bus is not pulled up, the DS2786 remains
in Sleep and cannot accumulate the charge current. This caution statement applies particularly to a battery that is
charged on a stand-alone charger.
PARAMETER MEASUREMENT
The DS2786 uses a Sigma Delta A/D converter to make measurements. The measurement sequence shown in
Figure 4 repeats continuously while the DS2786 is in Active mode. The V
and AIN1 conversion to allow for the V
temperature using its on-chip sensor instead of the AIN1 input. When the internal temperature measurement uses
the AIN1 conversion timeslot, V
1760ms to complete.
Figure 4. Measurement Sequence
SMOD = 1 AND [ ( SCL < V
OUT
is not activated. A full sequence of voltage measurements nominally takes
OUT
( SCL > V
output voltage to settle. The DS2786 can be configured to measure
IH
) OR ( SDA > V
7 of 22
IL
) AND ( SDA < V
DS2786 Stand-Alone OCV-Based Fuel Gauge
IH
)
IL
OUT
) ] for t
pin is activated t
SLEEP
PRE
before the AIN0

Related parts for DS2786G+