Current - Supply
180µA
Voltage - Supply
2 V ~ 9 V
Operating Temperature
-40°C ~ 85°C
Interface
I²C
Display Type
LCD
Configuration
40 Segment
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digits Or Characters
-
Lead Free Status / Rohs Status
 Details
Other names
933804620112::PCF8576T/1::PCF8576T/1
Philips Semiconductors
After acknowledgement, one or more command bytes (m)
follow which define the status of the addressed PCF8576s.
The last command byte is tagged with a cleared most
significant bit, the continuation bit C. The command bytes
are also acknowledged by all addressed PCF8576s on the
bus.
After the last command byte, a series of display data bytes
(n) may follow. These display bytes are stored in the
display RAM at the address specified by the data pointer
and the subaddress counter. Both data pointer and
subaddress counter are automatically updated and the
data is directed to the intended PCF8576 device. The
acknowledgement after each byte is made only by the (A0,
A1 and A2) addressed PCF8576. After the last display
byte, the I
2001 Oct 02
handbook, full pagewidth
Universal LCD driver for low multiplex rates
2
C-bus master issues a STOP condition (P).
SDA
SCL
START condition
SDA
SCL
S
Fig.13 Definition of START and STOP conditions.
data valid
data line
stable;
Fig.12 Bit transfer.
20
allowed
change
of data
7.8
The command decoder identifies command bytes that
arrive on the I
continuation bit C in their most significant bit position
(Fig.17). When this bit is set, it indicates that the next byte
of the transfer to arrive will also represent a command. If
this bit is reset, it indicates the last command byte of the
transfer. Further bytes will be regarded as display data.
The five commands available to the PCF8576 are defined
in Table 4.
Command decoder
2
C-bus. All available commands carry a
STOP condition
MBA607
P
MBC622
SDA
SCL
Product specification
PCF8576