CS5461A-ISZ Cirrus Logic Inc, CS5461A-ISZ Datasheet - Page 36

IC ENERGY METERING 1PHASE 24SSOP

CS5461A-ISZ

Manufacturer Part Number
CS5461A-ISZ
Description
IC ENERGY METERING 1PHASE 24SSOP
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS5461A-ISZ

Package / Case
24-SSOP
Input Impedance
30 KOhm
Measurement Error
0.1%
Voltage - I/o High
0.8V
Voltage - I/o Low
0.2V
Current - Supply
2.9mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Output Voltage Range
2.4 V to 2.6 V
Input Voltage Range
2.4 V to 2.6 V
Input Current
25 nA
Power Dissipation
500 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Input Voltage
5V
Supply Voltage Range
3.135V To 5.25V
No. Of Pins
24
Filter Terminals
SMD
No. Of Channels
2
Ic Generic Number
5461
Output Current Max
1µA
Rohs Compliant
Yes
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1552 - BOARD EVAL & SOFTWARE CS5461A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1095-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
114
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS5461A-ISZ
Quantity:
267
Part Number:
CS5461A-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
component present in the system during conversion
commands.
7.1.2.2 AC Offset Calibration Sequence
Corresponding offset registers I
should be cleared prior to initiating AC offset calibra-
tions. Initiate an AC offset calibration. The AC offset reg-
isters are updated with an offset value that reflects the
RMS output level. Upon completion of the AC offset cal-
ibration the AC offset is stored in the corresponding AC
offset register. The AC offset register value is subtract-
ed from each successive V
7.1.3 Gain Calibration Sequence
When performing gain calibrations, a reference signal
should be applied to the VIN± pins of the voltage and
IIN± pins of the current channels that represents the de-
sired maximum signal level.
setup for gain calibration.
For gain calibrations, there is an absolute limit on the
RMS voltage levels that are selected for the gain-cali-
bration input signals. The maximum value that the gain
registers can attain is 4. Therefore, if the signal level of
the applied input is low enough that it causes the
CS5461A to attempt to set either gain register higher
than 4, the gain calibration result will be invalid and all
CS5461A results obtained while performing measure-
ments will be invalid.
If the channel gain registers are initially set to a gain oth-
er then 1.0, AC gain calibration should be used.
7.1.3.1 AC Gain Calibration Sequence
The corresponding gain register should be set to 1.0,
unless a different initial gain value is desired. Initiate an
AC gain calibration. The AC gain calibration algorithm
computes the RMS value of the reference signal applied
to the channel inputs. The RMS register value is then di-
vided into 0.6 and the quotient is stored in the corre-
sponding
measurement will be multiplied by its corresponding AC
gain value.
36
R eference
Signal
CM + -
Figure 11. System Calibration of Gain
+
-
External
Connections
gain
IN+
IN-
register.
RMS
Figure 11
+
-
and I
Each
XG AIN
ACoff
RMS
shows the basic
and/or V
instantaneous
calculation.
+
-
ACoff
A typical rms calibration value which allows for reason-
able over-range margin would be 0.6 or 60% of the volt-
age and current channel’s maximum input voltage level.
Two examples of AC gain calibration and the updated
digital output codes of the channel’s instantaneous data
registers are shown in Figures 12 and 13. Figure 13
shows that a positive (or negative), DC-level signal can
be used even though an AC gain calibration is being ex-
Figure 13. Another Example of AC Gain Calibration
Sinewave
Sinewave
DC Signal
DC Signal
SIGNAL
SIGNAL
SIGNAL
After AC Gain Calibration (Vgain Register changed to approx. 0.65217)
SIGNAL
After AC Gain Calibration (Vgn Register changed to approx. 0.9223)
INPUT
INPUT
INPUT
INPUT
Figure 12. Example of AC Gain Calibration
-250 mV
-250 mV
250 mV
230 mV
-230 mV
-250 mV
Before AC Gain Calibration (Vgain Register = 1)
-230 mV
-250 mV
250 mV
230 mV
250 mV
230 mV
250 mV
230 mV
0 V
0 V
0 V
0 V
Before AC Gain Calibration (Vgn Register = 1)
V
RMS
V
V
V
RMS
Register =
RMS
RMS
Register = 0.600000
Register = 0.600000
Register =
230
/
√2
x
250
230
1
/
250
= 0.92
≈ 0.65054
-0.84853
-0.92231
CS5461A
-1.0000...
0.92231
0.84853
0.9999...
-0.92
0.92
Instantaneous Voltage
Instantaneous Voltage
-0.65217
-1.0000...
0.65217
0.9999...
0.92
0.6000
Register Values
Instantaneous Voltage
Register Values
Instantaneous Voltage
Register Values
DS661F2
Register Values

Related parts for CS5461A-ISZ