AH286-YL-13 Diodes Zetex, AH286-YL-13 Datasheet
AH286-YL-13
Specifications of AH286-YL-13
Related parts for AH286-YL-13
AH286-YL-13 Summary of contents
Page 1
... AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER General Description AH286 is a monolithic fan motor controller with Hall sensor’s capability. It contains two complementary open-drain transistors for motor’s coil driving, automatic lock current shutdown, and recovery protections. In addition, rotor-state detection (RD) output is for Rotor-state detection ...
Page 2
... Ordering Information Package Y : SOT89-5L Package Device Code AH286-YL-13 Y Notes Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied. Please visit our website at http://www.diodes.com/products/lead_free.html 2. Pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. Pin Assignment ...
Page 3
... Block Diagram Vdd 1 Regulator Hall Plate Amp. AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER Lock Shutdown and Automatic Recovery Control Logic 2 5 GND www.diodes.com AH286 DOB JULY 2009 © Diodes Incorporated ...
Page 4
... Thermal Resistance Junction-to-Case (Note 3) JA θ Notes: 3. should be confirmed with what heat sink thermal resistance heat sink contacting, JA Recommended Operating Conditions Symbol Characteristic Vdd Supply Voltage T Operating Ambient Temperature A AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER (T = 25°C) A Characteristics I O (AVE (PEAK θ ...
Page 5
... Output Zener-breakdown Voltage Truth Table IN- IN Magnetic Characteristics Symbol Characteristics Bop Operate Point Brp Release Point Bhy Hysteresis AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER = 25 °C, Vdd =12V, unless otherwise specified Conditions Operating V =24V OUT I =300mA O I =500mA O I =300mA O I =10mA O ...
Page 6
... Operating Characteristics DOB Brp 0 Magnetic Flux Density in Gauss AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER OFF OFF OP RP Vsat Vsat Bop Magnetic Flux Density in Gauss S Marking side N ( SOT89- www.diodes.com AH286 Brp 0 Bop JULY 2009 © Diodes Incorporated ...
Page 7
... D P (mW) D 900 800 700 600 500 400 300 200 100 0 0 Marking Information (1) SOT89-5L ( Top View ) 5 286 AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER 576 512 480 448 115 120 125 130 224 192 160 128 Power Dissipation Curve 25 ...
Page 8
... Package Information (1) SOT89-5L Sensor Location AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER (All Dimensions in mm www.diodes.com AH286 JULY 2009 © Diodes Incorporated ...
Page 9
... Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2009, Diodes Incorporated www.diodes.com AH286 Rev. 11 DS31030 HALL-EFFECT SMART FAN MOTOR CONTROLLER IMPORTANT NOTICE ...