NJM37770D3# NJR, NJM37770D3# Datasheet

no-image

NJM37770D3#

Manufacturer Part Number
NJM37770D3#
Description
IC STEPPER MOTOR DRIVER 16-DIP
Manufacturer
NJR
Datasheet

Specifications of NJM37770D3#

Applications
Stepper Motor Driver, 2 Phase
Number Of Outputs
1
Current - Output
1.3A
Voltage - Load
10 V ~ 55 V
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-20°C ~ 125°C
Mounting Type
Through Hole
Package / Case
16-DIP (0.325", 8.25mm), 12 Leads + 2 Fins
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NJM#37770D3
NJM#37770D3
■ GENERAL DESCRIPTION
LS-TTL compatible logic input stage, a current sensor, a
monostable multivibrator and a high power H-bridge output
stage. The NJM37770 is a high power version and
pincompatible with the NJM37717 and also NJM37770 is
a high voltage version with NJM3770A. Two NJM37770
and a small number of external components form a
complete control and drive unit stepper motor systems.
■ FEATURES
■ BLOCK DIAGRAM
Ver.2006-04-11
NJM37770 is a stepper motor driver, which consists of a
● Half-step and full-step operation
● Switched mode bipolar constant current drive
● Wide range of current control
● Wide voltage range
● Thermal overload protection
● Packages
STEPPER MOTOR DRIVER
5 to 1500mA
10 to 60 V
DIP16 (Batwing) / EMP20
Figure 1. Block diagram
■ PACKAGE OUTLINE
NJM37770D3
NJM37770E2
- 1 -

Related parts for NJM37770D3#

NJM37770D3# Summary of contents

Page 1

GENERAL DESCRIPTION NJM37770 is a stepper motor driver, which consists of a LS-TTL compatible logic input stage, a current sensor, a monostable multivibrator and a high power H-bridge output stage. The NJM37770 is a high power version and pincompatible ...

Page 2

PIN CONFIGURATION ■ PIN DESCRIPTION DIP EMP Symbol 3,14 3, 4,5, 4-7 GND 12,13 14- Phase ...

Page 3

FUNCTIONAL DESCRIPTION The NJM37770 is intended to drive a bipolar constant current through one winding of a 2-phase stepper motor. Current control is achieved through switched-mode regulation, see figure 3 and 4. Three different current levels and zero current ...

Page 4

Current level selection. The status of I and I inputs determines the current level in the motor winding. Three fixed current levels can selected according to the table below. Motor current I 0 High level 100% L ...

Page 5

ABSOLUTE MAXIMUM RATINGS Parameter Voltage Logic supply Motor supply Logic inputs Comparator input Reference input Current Motor output current Logic inputs Analog inputs Temperature Operating junction temperature Storage temperature ■ RECOMMENDED OPERATING CONDITIONS (T Parameter Logic supply voltage Motor ...

Page 6

ELECTRICAL CHARACTERISTICS Electrical characteristics over recommended operating conditions, unless otherwise specified.T R =56kΩ T Parameter General Supply current Total power dissipation Turn-off delay Thermal shutdown junction temperature Logic Inputs Logic HIGH input voltage Logic LOW input voltage Logic HIGH ...

Page 7

APPLICATIONS INFORMATION Motor selection Some stepper motors are not designed for continuous operation at maximum current. As the circuit drives a constant current through the motor, its temperature can increase, both at low- and high-speed operation. Some stepper motors ...

Page 8

Analog control As the current levels can be continuously controlled by modulating the V Sensor resistor The R resistor should noninductive type power resistor. A 0.5 ohm resistor, tolerance ≤ 1 good choice for S ...

Page 9

Heatsinking The junction temperature of the chip highly effects the lifetime of the circuit. In high-current applications, the heatsinking must be carefully considered. The Rth of the NJM37770 can be reduced by soldering the ground pins to a suitable copper ...

Page 10

TYPICAL CHARACTERISTICS Figure 11. Typical source saturation vs. output current Figure 13. Typical sink saturation vs. output current Figure 15. Allowable power dissipation vs. ambient temperature - 10 - Figure 12. Typical lower diode voltage drop vs. recirculating current ...