LTC3455EUF#TRPBF Linear Technology, LTC3455EUF#TRPBF Datasheet - Page 21

no-image

LTC3455EUF#TRPBF

Manufacturer Part Number
LTC3455EUF#TRPBF
Description
IC CONV DC/DC DUAL USBBATT 24QFN
Manufacturer
Linear Technology
Datasheet

Specifications of LTC3455EUF#TRPBF

Applications
Handheld/Mobile Devices
Voltage - Supply
3 V ~ 6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC3455EUF#TRPBFLTC3455EUF
Manufacturer:
LINEAR
Quantity:
2 355
Company:
Part Number:
LTC3455EUF#TRPBFLTC3455EUF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC3455EUF#TRPBFLTC3455EUF#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC3455EUF#TRPBFLTC3455EUF#TR
Manufacturer:
LINEAR
Quantity:
12
Company:
Part Number:
LTC3455EUF#TRPBF
Manufacturer:
LTC
Quantity:
20
APPLICATIONS INFORMATION
Programming Charge Current
The maximum charge current is programmed using one
external resistor connected between the PROG pin and
GND (use the closest 1% resistor value):
If only USB power is used (no wall adapter), select the
R
charge current at 500mA. If a wall adapter is also used,
I
value), and the USB power manager will automatically
throttle back the charge current to below 500mA when
under USB power.
Monitoring Charge Current
The voltage on the PROG pin is an accurate indication of the
battery charge current under all charging conditions.
Capacitance on the PROG pin should be minimized to
ensure loop stability when in constant-current mode. Do
not place a capacitor directly from the PROG pin to ground.
Adding an external R-C network (see Figure 11) allows the
monitoring of average, rather than instantaneous, battery
charge current. Average charge current is typically of more
interest to the user, especially when the LTC3455/LTC3455-1
are USB powered, as the battery charge current varies
signifi cantly with normal load transients.
Programming the Battery Charger Timer
An external capacitor on the TIMER pin sets the total charge
time. When this timer elapses the charge cycle terminates
CHARGE
PROG
R
I
BAT
PROG
value to be 2.49kΩ (or larger) to set the maximum
= 1000 • V
can be programmed up to 1A (with a 1.24kΩ R
Figure 11. Monitoring Average Charge Current
= 1000 • 1.23V / I
LTC3455-1
LTC3455/
GND
PROG
25
PROG
2
R
/ R
PROG
PROG
BAT
C
10k
FILTER
3455 F11
CHARGE
CURRENT
MONITOR
CIRCUITRY
PROG
and the CHRG pin assumes a high impedance state. The
total charge time is programmed as:
For most applications, a two to three hour timer will provide
suffi cient time to completely recharge the battery. But for
some applications with larger capacity batteries, four to
fi ve hours of charging may be needed. A potential problem
arises with setting such long timer periods (longer than 3
hours): If the battery is just below the recharge threshold
(meaning it is almost fully charged) it will still be charged
for the total timer period when external power is applied.
This means that the battery will be continually charged
at a very, very low charge current for the full four to fi ve
hours, even if the battery reaches the fl oat voltage right
away. This type of charging is undesirable for some battery
applications, and can be avoided by choosing a shorter
timer period (but not less than 1 hour). At the end of a
charge cycle, the LTC3455 will measure the battery voltage
to see if it is above the 4.05V recharge threshold. If it is
not above 4.05V, a new charge cycle will begin, repeating
until the battery voltage is above 4.05V. Even if the bat-
tery charges to just above the 4.05V threshold using this
shorter timer method, more than 90% charge capacity
should easily be reached (Note: The LTC3455-1 recharge
threshold is 3.95V instead of 4.05V).
Trickle Charge and Defective Battery Detection
If the battery voltage is below 2.85V at the beginning of the
charge cycle, the charger goes into trickle charge mode,
reducing the charge current to 10% of its programmed
full-scale value. If the low battery voltage remains for one
quarter of the programmed total charge time, the battery is
assumed to be defective, the charge cycle is terminated, and
the CHRG pin goes to a high impedance state. This fault is
cleared if any of the following occurs: The battery voltage
rises above 2.85V, external power is removed and reapplied,
the PROG pin is fl oated temporarily, or the SUSPEND pin
is temporarily pulled high (if the LTC3455/LTC3455-1 are
under USB power). The device will still operate normally
from USB or wall power even if the charger has turned
off due to a trickle-charge timeout.
T
TIMER
(hours) = C
LTC3455/LTC3455-1
TIMER
• (3 hours) / (0.1μF)
21
3455fc