LM96000CIMT/NOPB National Semiconductor, LM96000CIMT/NOPB Datasheet - Page 27

IC HDWR MON W/FAN CTRL 24-TSSOP

LM96000CIMT/NOPB

Manufacturer Part Number
LM96000CIMT/NOPB
Description
IC HDWR MON W/FAN CTRL 24-TSSOP
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM96000CIMT/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Control, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Ic Output Type
Digital
Sensing Accuracy Range
± 2.5°C
Temperature Sensing Range
0°C To +85°C
Supply Current
530µA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
8bit
Sensor Case Style
TSSOP
No. Of Pins
24
Rohs Compliant
Yes
Accuracy %
3°C
For Use With
LM96000EVAL - BOARD EVALUATION LM96000
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM96000CIMT
*LM96000CIMT/NOPB
LM96000CIMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM96000CIMT/NOPB
Manufacturer:
EPCOS
Quantity:
3 186
6Ah
6Bh
6Ch
Register
Address
4.19 Registers 6A-6Ch: Absolute Temperature Limit
In the Auto Fan mode, if a zone exceeds the temperature set in the Absolute Temperature Limit register, all of the PWM outputs
will incresase its duty cycle to 100%. This is a safety feature that attempts to cool the system if there is a potentially catastrophic
thermal event. If set to 80h (-128°C), the feature is disabled. Default=100°C=64h
These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
these registers shall have no effect. After power up the default values are used whenever the Ready/Lock/Start/Override register
Start bit is cleared even though modifications to these registers are possible.
R/W
R/W
R/W
Read/
Write
Zone1 Absolute Temp Limit
Zone2 Absolute Temp Limit
Zone3 Absolute Temp Limit
Register
Name
Temperature
Temperature
TABLE 10. Temperature Limit vs Register Setting
−127°C
−127°C
−50°C
127°C
TABLE 11. Absolute Limit vs Register Setting
−50°C
127°C
50°C
50°C
0°C
0°C
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(MSB)
Reading (Decimal)
Reading (Decimal)
Bit 7
7
7
7
−127
−127
−50
127
−50
127
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1
50
50
0
0
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
6
6
6
5
5
5
Reading (Hex)
Reading (Hex)
4
4
4
CEh
CEh
81h
00h
32h
7Fh
81h
00h
32h
7Fh
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
3
3
2
2
2
1
1
1
(LSB)
Bit 0
0
0
0
Default
Value
64h
64h
64h
www.national.com
Lock?