LM96163CISD/NOPB National Semiconductor, LM96163CISD/NOPB Datasheet - Page 39

IC TEMP SENSOR DGTL REMOTE 10LLP

LM96163CISD/NOPB

Manufacturer Part Number
LM96163CISD/NOPB
Description
IC TEMP SENSOR DGTL REMOTE 10LLP
Manufacturer
National Semiconductor
Series
PowerWise®, TruTherm®r
Datasheet

Specifications of LM96163CISD/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank, Tach
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-LLP
Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Resolution
10+SignBit
Package Type
LLP EP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM96163CISDTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM96163CISD/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM96163CISD/NOPB
0
5.
6.
7.
8.
9.
Noise coupling into the digital lines greater than 400 mVp-p
(typical hysteresis) and undershoot less than 500 mV below
Avoid routing diode traces in close proximity to power
supply switching or filtering inductors.
Avoid running diode traces close to or parallel to high
speed digital and bus lines. Diode traces should be kept
at least 2 cm apart from the high speed digital traces.
If it is necessary to cross high speed digital traces, the
diode traces and the high speed digital traces should
cross at a 90 degree angle.
The ideal place to connect the LM96163's GND pin is as
close as possible to the Processor's GND associated
with the sense diode.
Leakage current between D+ and GND should be kept
to a minimum. Thirteen nano-amperes of leakage can
cause as much as 0.2°C of error in the diode temperature
reading. Keeping the printed circuit board as clean as
possible will minimize leakage current.
39
GND, may prevent successful SMBus communication with
the LM96163. SMBus no acknowledge is the most common
symptom, causing unnecessary traffic on the bus. Although
the SMBus maximum frequency of communication is rather
low (100 kHz max), care still needs to be taken to ensure
proper termination within a system with multiple parts on the
bus and long printed circuit board traces. An RC lowpass filter
with a 3 dB corner frequency of about 40 MHz is included on
the LM96163's SMBCLK input. Additional resistance can be
added in series with the SMBDAT and SMBCLK lines to fur-
ther help filter noise and ringing. Minimize noise coupling by
keeping digital traces out of switching power supply areas as
well as ensuring that digital lines containing high speed data
communications cross at right angles to the SMBDAT and
SMBCLK lines.
www.national.com