MAX6652AUB+T Maxim Integrated Products, MAX6652AUB+T Datasheet - Page 7

IC TEMP SENS/MON 10-UMAX

MAX6652AUB+T

Manufacturer Part Number
MAX6652AUB+T
Description
IC TEMP SENS/MON 10-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6652AUB+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
7 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Dc
0635
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MAX6652AUB+T
MAX6652AUB+TTR
Table 4. Configuration Register (Address 41h, Power-Up Default = 00h)
Table 5. Interrupt Status Register (Address 41h, Power-Up Default = 00h)
5, 6, 7
BIT
BIT
0
1
2
3
4
5
6
7
0
1
2
3
4
Temperature Error
Interrupt Enable
Line Frequency
Interrupt Clear
2.5V
3.3V
12V
Short Cycle
V
Reserved
Start/Stop
Reserved
Reserved
CC
Temperature Sensor and System Monitor
NAME
NAME
Select
Reset
IN
_______________________________________________________________________________________
IN
IN
Error
Error
Error
Error
READ/WRITE
READ/WRITE
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
This bit controls the monitoring loop. Setting the bit to 0 stops the
monitoring loop and puts the device into shutdown mode. The I
interface is still active during the shutdown mode. Setting the bit to 1 starts
the monitoring cycle. All high/low limits should be set before setting this
bit to 1.
This bit is used to enable or disable the interrupt output. Setting the bit to
1 enabes the interrupt output; setting the bit to 0 disables the interrupt
output.
This bit is used to clear the interrupt output when it is set to high. It will not
affect the interrupt status register. The monitoring loop will not start until
the bit is set to 0.
This bit controls the internal clock frequency. Setting the bit to 1 changes
the clock frequency to 51.2kHz from 61.4kHz. This can improve the
measurement accuracy when the power-line frequency is at 50Hz.
This bit reduces the conversion rate by a factor of four when it is set to 1.
This bit is used as a reset signal for the register initialization. The 1 of this
bit will reset all the register values into the power-up default mode,
including bit 7 itself.
A 1 indicates either a high or low limit has been exceeded at the 2.5V
input.
A 1 indicates either a high or low limit has been exceeded at the 12V
input.
A 1 indicates either a high or low limit has been exceeded at the 3.3V
input.
A 1 indicates either a high or low limit has been exceeded at the V
A 1 indicates either a high or low limit has been exceeded at the internal
temperature sensor. The conditions that will generate and clear this bit
depend on the temperature interrupt mode selected by bits 0 and 1 in the
temperature configuration register.
in a 10-Pin µMAX
DESCRIPTION
DESCRIPTION
2
C/SMBus
CC
IN
IN
input.
IN
7