MAX6693UP9A+ Maxim Integrated Products, MAX6693UP9A+ Datasheet - Page 16

IC TEMP MONITOR 7CH 20-TSSOP

MAX6693UP9A+

Manufacturer Part Number
MAX6693UP9A+
Description
IC TEMP MONITOR 7CH 20-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6693UP9A+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
20-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7-Channel Precision Temperature Monitor
with Beta Compensation
Table 8. Status 2 Register
Table 9. Status 3 Register
16
7 (MSB)
7 (MSB)
BIT
BIT
______________________________________________________________________________________
6
5
4
3
2
1
0
6
5
4
3
2
1
0
Remote 6 OVERT
Remote 5 OVERT
Remote 4 OVERT
Remote 1 OVERT
Diode fault 6
Diode fault 5
Diode fault 4
Diode fault 3
Diode fault 2
Diode fault 1
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
NAME
NAME
STATE
STATE
POR
POR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Channel 6 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 6 remote-diode temperature exceeds the temperature
threshold limit in the remote 6 OVERT high-limit register.
Channel 5 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 5 remote-diode temperature exceeds the temperature
threshold limit in the remote 5 OVERT high-limit register.
Channel 4 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
Channel 6 Remote-Diode Fault Bit. This bit is set to 1 when DXP6 and DXN6
are open circuit or when DXP6 is connected to V
Channel 5 Remote-Diode Fault Bit. This bit is set to 1 when DXP5 and DXN5
are open circuit or when DXP5 is connected to V
Channel 4 Remote-Diode Fault Bit. This bit is set to 1 when DXP4 and DXN4
are open circuit or when DXP4 is connected to V
Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3
are open circuit or when DXP3 is connected to V
Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2
are open circuit or when DXP2 is connected to V
Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1
are open circuit or when DXP1 is connected to V
FUNCTION
FUNCTION
CC
CC
CC
CC
CC
CC
.
.
.
.
.
.

Related parts for MAX6693UP9A+