Specifications of MAX6662MSA+T

Function
Temp Sensor, Watchdog
Topology
ADC, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 150°C
Output Type
SPI™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Full Temp Accuracy
+/- 2.5 C
Digital Output - Bus Interface
Serial (3-Wire, SPI)
Digital Output - Number Of Bits
12 bit + Sign
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12-Bit + Sign Temperature Sensor with
SPI-Compatible Serial Interface
The MAX6662 continuously converts its die tempera-
ture into a digital value using its integrated ADC.
Temperature data is updated twice a second. The
resulting data is readable at any time through the SPI-
compatible serial interface.
Figure 1 shows the simplified functional diagram of the
MAX6662. Its internal current sources force 100µA and
10µA currents through a diode (diode-connected tran-
sistor), while the integrating ADC measures the voltage
difference. The difference in voltage corresponds to the
die temperature. The result is stored in the Temperature
register. The control logic unit compares the tempera-
ture and the temperature limit settings stored in the reg-
isters to determine whether a fault condition has
occurred.
(V
4
CC
_______________________________________________________________________________________
= +3V, T
PIN
1
2
3
4
5
6
7
8
A
= +25°C, unless otherwise noted.)
ALERT
NAME
SCLK
GND
V
SIO
CS
OT
NC
CC
Detailed Description
Serial-Clock Input
Chip Select Input. Set low to enable the serial interface for data input/output.
Serial-Data Input/Output. Bidirectional data input and output for serial interface.
Ground
Overtemperature Output. Open-drain output requires a pullup resistor to V
Alert Output. Open-drain output requires a pullup resistor to V
No Connection. Do not make a connection to this pin.
Supply Voltage Input. Bypass to GND with a 0.1µF capacitor as close to V
12
10
8
6
4
2
0
-50
Typical Operating Characteristics (continued)
SHUTDOWN CURRENT
V
0
VS.
CC
V
TEMPERATURE (°C)
CC
= +3.0V
TEMPERATURE
= +5.0V
V
CC
50
= +3.3V
The ALERT is an open-drain active-low (default, also
programmable active-high) output used to alert the sys-
tem to temperature faults. ALERT can be programmed
to operate in either one of two modes: comparator or
interrupt mode.
In the interrupt mode, the MAX6662 ALERT pin asserts
an alarm for an undertemperature (T
as for an overtemperature (T
fault has occurred, it remains active indefinitely, regard-
less of condition. ALERT is unconditionally deasserted
(even if Temperature is still out of limits) by reading the
temperature register. ALERT only asserts again if the
temperature crosses the hysteresis, thereby corre-
sponding to the fault (T
the ALERT.
100
FUNCTION
150
CC
.
LOW
Temperature Fault Alert
or T
HIGH
Pin Description
CC
CC
HIGH
.
as possible.