MAX6649MUA+T Maxim Integrated Products, MAX6649MUA+T Datasheet - Page 5

no-image

MAX6649MUA+T

Manufacturer Part Number
MAX6649MUA+T
Description
IC SENSOR REMOTE SMBUS 8UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6649MUA+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-55°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Full Temp Accuracy
+/- 3 C, +/- 3.2 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX6646/MAX6647/MAX6649 are temperature sen-
sors designed to work in conjunction with a microproces-
sor or other intelligence in thermostatic, process-control,
or monitoring applications. Communication with the
MAX6646/MAX6647/MAX6649 occurs through the
SMBus-compatible serial interface and dedicated alert
and overtemperature outputs. ALERT asserts if the mea-
sured local or remote temperature is greater than the
software-programmed ALERT high limit or less than the
ALERT low limit in the MAX6649. ALERT also asserts, in
the MAX6649, if the remote-sensing diode pins are short-
ed or unconnected. The overtemperature alarm, OVERT,
asserts if the software-programmed OVERT limit is
exceeded. OVERT can be connected to fans, a system
shutdown, a clock throttle control, or other thermal-man-
agement circuitry.
The MAX6646/MAX6647/MAX6649 convert temperatures
to digital data either at a programmed rate or in single
conversions. Temperature data is represented as 11 bits,
with the LSB equal to 0.125°C. The “main” temperature
data registers (at addresses 00h and 01h) are 8-bit regis-
ters that represent the data as 8 bits with the full-scale
reading indicating the diode fault status (Table 1). The
remaining 3 bits of temperature data are available in the
“extended” registers at addresses 11h and 10h (Table 2).
PIN
1
2
3
4
5
6
7
8
+145°C Precision SMBus-Compatible Remote/
Local Sensors with Overtemperature Alarms
_______________________________________________________________________________________
OVERT
ALERT
NAME
SCLK
GND
DXN
SDA
V
DXP
CC
Detailed Description
Supply Voltage Input, 3V to 5.5V. Bypass V
resistor is recommended but not required for additional noise filtering.
Combined Remote-Diode Current Source and A/D Positive Input for Remote-Diode Channel. DO
NOT LEAVE DXP FLOATING; connect DXP to DXN if no remote diode is used. Place a 2200pF
capacitor between DXP and DXN for noise filtering.
Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally connected to
ground.
Overtemperature Alert/Interrupt Output, Open Drain. OVERT is logic low when the temperature is
above the software-programmed threshold.
Ground
SMBus Alert (Interrupt) Output, Open Drain. ALERT asserts when temperature exceeds limits
(high or low temperature). ALERT stays asserted until acknowledged by either reading the status
register or by successfully responding to an alert response address, provided that the fault
condition no longer exists. See the ALERT Interrupts section.
SMBus Serial-Data Input/Output, Open Drain
SMBus Serial-Clock Input
The averaging ADC integrates over a 60ms period
(each channel, typically), with excellent noise rejection.
The multiplexer automatically steers bias currents
through the remote and local diodes. The ADC and
associated circuitry measure each diode’s forward volt-
age and compute the temperature based on this volt-
age. Both channels are automatically converted once
the conversion process has started, either in free-run-
ning or single-shot mode. If one of the two channels is
not used, the device still performs both measurements,
and the results of the unused channel can be ignored.
If the remote-diode channel is unused, connect DXP to
DXN rather than leaving the inputs open.
Table 1. Main Temperature Data Register
Format (00h, 01h)
CC
FUNCTION
(short or open)
to GND with a 0.1µF capacitor. A 200Ω series
TEMP (°C)
Diode fault
+145
+130
+128
+25
<0
0
ADC and Multiplexer
Pin Description
DIGITAL OUTPUT
1001 0001
1000 0010
1000 0000
0001 1001
0000 0000
0000 0000
1111 1111
5

Related parts for MAX6649MUA+T