AD7415ART-1500RL7 Analog Devices Inc, AD7415ART-1500RL7 Datasheet - Page 4

IC SENSOR TEMP 10BIT SOT23-5 TR

AD7415ART-1500RL7

Manufacturer Part Number
AD7415ART-1500RL7
Description
IC SENSOR TEMP 10BIT SOT23-5 TR
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7415ART-1500RL7

Rohs Status
RoHS non-compliant
Function
Temp Monitoring System (Sensor)
Topology
ADC, Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
AD7414/AD7415
Parameter
AC ELECTRICAL CHARACTERISTICS
1
2
3
4
5
6
7
8
9
Accuracy specifications apply only to voltages listed under Test Conditions. See Temperature Accuracy vs. Supply section for typical accuracy performance over the
full V
100% production tested at 40°C to these limits.
These current values can be used to determine average power consumption at different one-shot conversion rates. Average power consumption at the automatic
conversion rate of 1.25 kHz is 940 μW.
This peak supply current is required for 29 μs (the conversion time plus power-up time) out of every 800 μs (the conversion rate).
These current values are derived by not issuing a stop condition at the end of a write or read, thus preventing the part from going into a conversion.
The current is derived assuming a 400 kHz serial clock being active continuously.
On power-up, the initial input current, I
The SDA and SCL timing is measured with the input filters turned on so as to meet the fast mode I
rate but has a negative effect on the EMC behavior of the part.
Guaranteed by design. Not tested in production.
Serial Clock Period, t
Data In Setup Time to SCL High, t
Data Out Stable after SCL Low, t
SDA Low Setup Time to SCL Low
SDA High Hold Time after SCL High
SDA and SCL Fall Time, t
Data Hold Time, t
Power-Up Time
(Start Condition), t
(Stop Condition), t
DD
supply range.
7
1
4
5
6
IN
3
8, 9
, on the AS pin is typically 50 μA.
2
DATA OUT
DATA IN
SDA
SDA
SCL
Figure 2. Diagram for Serial Bus Timing
t
4
A Version
2.5
50
0
50
50
90
35
4
Rev. F | Page 4 of 20
t
t
2
1
t
7
t
3
Unit
μs min
ns min
ns min
ns min
ns min
ns max
ns min
μs typ
2
C specification. Switching off the input filters improves the transfer
t
6
Test Conditions/Comments
See Figure 2
See Figure 2
See Figure 2
See Figure 2
See Figure 2
See Figure 2
See Figure 2
t
5