TC9400CPD Microchip Technology, TC9400CPD Datasheet - Page 9

IC V-FREQ/FREQ-V CONV 14DIP

TC9400CPD

Manufacturer Part Number
TC9400CPD
Description
IC V-FREQ/FREQ-V CONV 14DIP
Manufacturer
Microchip Technology
Type
Volt to Freq & Freq to Voltr
Datasheets

Specifications of TC9400CPD

Package / Case
14-DIP (0.300", 7.62mm)
Frequency - Max
100kHz
Full Scale
±40ppm/°C
Linearity
±0.05%
Mounting Type
Through Hole
Supply Voltage (max)
15 V
Supply Voltage (min)
8 V
Maximum Operating Temperature
70 C
Minimum Operating Temperature
0 C
Dual Supply Voltage
+/- 5 V
Full Scale Frequency
100 KHz
Linearity Error
+/- 0.25 % FSR
Maximum Dual Supply Voltage
+/- 7.5 V
Minimum Dual Supply Voltage
+/- 4 V
Mounting Style
Through Hole
Operating Supply Voltage
9 V or 12 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
158-1140
158-1140

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TC9400CPD
Manufacturer:
MIT
Quantity:
6 234
Part Number:
TC9400CPD
Manufacturer:
TELCOM
Quantity:
20 000
TC9400/9401/9402
3.2
Voltage-to-Time Measurements
The TC9400 output can be measured in the time
domain as well as the frequency domain. Some micro-
computers, for example, have extensive timing capabil-
ity, but limited counter capability. Also, the response
time of a time domain measurement is only the period
between two output pulses, while the frequency
measurement must accumulate pulses during the
entire counter time-base period.
Time measurements can be made from either the
TC9400’s PULSE FREQ OUT output, or from the
FREQ/2 OUT output. The FREQ/2 OUT output
changes state on the rising edge of PULSE FREQ
OUT, so FREQ/2 OUT is a symmetrical square wave at
one-half the pulse output frequency. Timing measure-
ments can, therefore, be made between successive
PULSE FREQ OUT pulses, or while FREQ/2 OUT is
high (or low).
© 2007 Microchip Technology Inc.
DS21483D-page 9