IR3820AMTRPBF International Rectifier, IR3820AMTRPBF Datasheet - Page 10

IC REG SYNC BUCK 14A 5X6 15QFN

IR3820AMTRPBF

Manufacturer Part Number
IR3820AMTRPBF
Description
IC REG SYNC BUCK 14A 5X6 15QFN
Manufacturer
International Rectifier
Series
SupIRBuck™r
Type
Step-Down (Buck)r
Datasheet

Specifications of IR3820AMTRPBF

Internal Switch(s)
Yes
Synchronous Rectifier
Yes
Number Of Outputs
1
Voltage - Output
0.6 ~ 12 V
Current - Output
14A
Frequency - Switching
300kHz
Voltage - Input
2.5 ~ 21 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
15-PowerVQFN
Power - Output
3.7W
Part Status
Active
Package
PQFN / 5 x 6
Circuit
Single Output
Iout (a)
14
Switch Freq (khz)
300
Input Range (v)
2.5 - 21
Output Range (v)
0.6 - 12
Ocp Otp Uvlo Pre-bias Soft Start And
PGOOD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
IR3820AMTRPBFTR
11/04/08
Over-Current Protection
The over-current protection is performed by
sensing current through the R
side MOSFET. This method enhances the
converter’s efficiency and reduces cost by
eliminating a current sense resistor. As shown in
figure 7, an external resistor (R
between OCSet pin and the inductor point which
sets the current limit set point.
The internal current source develops a voltage
across R
turned on, the inductor current flows through the
Q2 and results a voltage which is given by:
The critical inductor current can be calculated by
setting:
Fig. 7: Connection of over current sensing resistor
An over-current is detected if the OCSet pin goes
below ground. This trips the OCP comparator
and cycles the soft start function in hiccup mode.
The hiccup is performed by charging and
discharging the soft-start capacitor in a certain
slope rate. As shown in figure 8 a 3uA current
source is used to discharge the soft-start
capacitor.
The OCP comparator resets after every soft start
cycle. The converter stays in this mode until the
overload or short circuit is removed. The
converter will automatically recover.
V
OCSet
V
I
OCSet
SET
SET
=
(I
=
. When the low side MOSFET is
=
OCSet
I
(I
L
OCSet
(
critical
R
)
R
OCSet
=
OCSet
R
OCSet
)
)
R
(R
DS
(R
(
on
DS(on)
DS(on)
I
OCSet
)
SET
DS(on)
) is connected
) I
I
L
L
)
=
of the low
--(
0
--(
3
)
2
)
The OCP circuit starts sampling current when the
low gate drive is about 3V. The OCSet pin is
internally clamped about 1.5V during on time of
high side gate to prevent false trigging, figure 9
shows the OCSet pin during one switching cycle.
As shown, there is about 150ns delay to mask
the dead time. Since this node contains switching
noises, this delay also functions as a filter.
The value of R
circuit to ensure that the over-current protection
circuit activates as expected. The IR3820A
current limit is designed primarily as disaster
preventing, and doesn't operate as a precision
current regulator.
Fig. 9: OCset pin during normal condition
Fig. 8: 3uA current source for discharging
Ch1: Inductor point, Ch3:OCSet
I
OCSet
soft-start capacitor during hiccup
*R
OCSet
SET
Deadtime
should be checked in an actual
IR3820AMPbF
Blanking time
Clamp voltage
PD-60330
10