MAX4893BETB+T Maxim Integrated Products, MAX4893BETB+T Datasheet
MAX4893BETB+T
Specifications of MAX4893BETB+T
Related parts for MAX4893BETB+T
MAX4893BETB+T Summary of contents
Page 1
... MAX4893BETB -40°C to +85° Exposed pad. **Future product—contact factory for availability. ________________________________________________________________ Maxim Integrated Products For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. Current Limit in TDFN o Overvoltage Protection Up to 28V o Preset Overvoltage Trip Level 5 ...
Page 2
Overvoltage Protection Controllers with Current Limit in TDFN ABSOLUTE MAXIMUM RATINGS (All voltages referenced to GND.) IN ............................................................................-0.3V to +30V GATE ......................................................................-0.3V to +12V EN, , OV, FLAGI, BTA, BTB ................................-0.3V to +6V CB Continuous Power Dissipation (T = +70°C) ...
Page 3
Overvoltage Protection Controllers with ELECTRICAL CHARACTERISTICS (continued +5V (MAX4881/MAX4883/MAX4893B values are +25°C.) (Note 1) A PARAMETER SYMBOL GATE GATE Voltage GATE Pulldown Current TIMING Startup Delay OV Blanking Time t OV-BLANK GATE Turn-On ...
Page 4
Overvoltage Protection Controllers with Current Limit in TDFN ( +25°C, unless otherwise noted CURRENT vs. INPUT VOLTAGE IN BTA 400 350 300 OVLO ...
Page 5
Overvoltage Protection Controllers with ( +25°C, unless otherwise noted CURRENT LIMIT vs. TEMPERATURE (MAX4884) 800 700 600 500 400 300 200 2.7V BTB 100 ...
Page 6
Overvoltage Protection Controllers with Current Limit in TDFN PIN NAME Input the power input for the OVP charge pump. Bypass IN to GND with a 1µF or larger 1 IN capacitor. Active-Low Enable Input. Drive EN high to ...
Page 7
Overvoltage Protection Controllers with V V UVLO IN 1.2V t GON t START V GATE 0. Figure 1. Startup Timing Diagram 7V/ OVLO 4V/5V t GOFF V GATE 0. Figure 2. Shutdown Timing ...
Page 8
Overvoltage Protection Controllers with Current Limit in TDFN t t BLANK BLANK LOAD CURRENT ON SWITCH STATUS FLAGI (a) MAX4881/MAX4882/MAX4883B/MAX4884B/MAX4893B t t BLANK BLANK LOAD CURRENT ON SWITCH STATUS FLAGI (b) MAX4883C/MAX4884C Figure 5. Current-Limit Fault Timing Overcurrent Flag Output ...
Page 9
Overvoltage Protection Controllers with EN IN OVLO CHARGE PUMP IN UVLO OV 1.1A/0.7A LIMIT I FLAGI REF CHARGE PUMP BLANKING TIME AND LATCHOFF LOGIC MAX4881/MAX4882 MAX4883B/MAX4884B GND Figure 7a. MAX4881/MAX4882/MAX4883B/MAX4884B/ MAX4893B Functional Diagram resets if the overcurrent condition disappears before ...
Page 10
Overvoltage Protection Controllers with Current Limit in TDFN Table 1. MOSFET Suggestions CONFIGURATION/ PART PACKAGE Single/SC70-6 Si1426DH FDG315N Single/SC70 1MΩ 1.5kΩ DISCHARGE CHARGE-CURRENT- RESISTANCE LIMIT RESISTOR HIGH STORAGE VOLTAGE 100pF CAPACITOR DC SOURCE Figure ...
Page 11
Overvoltage Protection Controllers with 4.4V ADAPTER WITH BUILT-IN CHARGER IN GATE BTA V IO 1.1A/0.7A BTB MAX4882/ MAX4884 FLAGI GND Figure 12. Connection to an AC-DC Adapter without a Built-In Battery Charger ground-connected pad as the only ...
Page 12
Overvoltage Protection Controllers with Current Limit in TDFN (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information go to www.maxim-ic.com/packages.) 12 ______________________________________________________________________________________ Package Information PACKAGE OUTLINE, 6,8,10 & 14L, ...
Page 13
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 13 © 2006 Maxim Integrated Products ...