KS8999 Micrel Inc, KS8999 Datasheet - Page 27

IC SWITCH 10/100 9PORT 208PQFP

KS8999

Manufacturer Part Number
KS8999
Description
IC SWITCH 10/100 9PORT 208PQFP
Manufacturer
Micrel Inc
Datasheets

Specifications of KS8999

Applications
*
Mounting Type
Surface Mount
Package / Case
208-MQFP, 208-PQFP
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII/SNI
Power Supply Type
Analog/Digital
Package Type
PQFP
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Mounting
Surface Mount
Jtag Support
No
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
576-1023 - BOARD EVAL EXPERIMENT FOR KS8999
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KS8999
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KS8999
Manufacturer:
PRX
Quantity:
20 000
Part Number:
KS8999I
Manufacturer:
Micrel Inc
Quantity:
10 000
The table below briefly summarizes priority features. For more detailed settings see the EEPROM register description.
VLAN Operation
The VLAN’s are setup by programming the VLAN Mask Registers in the EEPROM. The perspective of the VLAN is from the
input port and which output ports it sees directly through the switch. For example if port 1 only participated in a VLAN with ports
2 and 9 then one would set bits 0 and 7 in register 13 (Port 1 VLAN Mask Register). Note that different ports can be setup
independently. An example of this would be where a router is connected to port 9 and each of the other ports would work
autonomously. In this configuration ports 1 through 8 would only set the mask for port 9 and port 9 would set the mask for ports1
through 8. In this way, the router could see all ports and each of the other individual ports would only communicate with the
router.
All multicast and broadcast frames adhere to the VLAN configuration. Unicast frame treatment is a function of register 2 bit
0. If this bit is set then unicast frames only see ports within their VLAN. If this bit is cleared unicast frames can traverse VLAN’s.
VLAN tags can be added or removed on a per port basis. Further, there are provisions to specify the tag value to be inserted
on a per port basis.
The table below briefly summarizes VLAN features. For more detailed settings see the EEPROM register description.
Station MAC Address (control frames only)
The MAC source address can be programmed as used in flow control frames. The table below briefly summarizes this
programmable feature.
January 2005
KS8999
Register(s)
2
2
4-12
4-12
40-47
4-12
3
4-12
Register(s)
4-12
4-12
2
13-21
22-39
Register(s)
48-53
Bit(s)
3-2
1
0
5
7-0
4
7-0
3
Bit(s)
2
1
0
7-0
7-0
Bit(s)
7-0
Global/Port
Global
Global
Port
Port
Global
Port
Global
Port
Global/Port
Port
Port
Global
Port
Port
Global/Port
Global
Description
General
Priority Control Scheme: Transmit buffer high/low interleave control
Priority Buffer Reserve: Reserves 6KB of the buffer for high priority traffic
Enable Port Queue Split: Splits the transmit queue on the desired port for high and low
priority traffic
DSCP Priority
Enable Port DSCP: Looks at DSCP field in IP header to decide high or low priority
DSCP Priority Points: Fully decoded 64 bit register used to determine priority from
DSCP field (6 bits) in the IP header
802.1p Priority
Enable Port 802.1p Priority: Uses the 802.1p priority tag (3 bits) to determine frame
priority
Priority Classification: Determines which tag values have high priority
Per Port Priority
Enable Port Priority: Determines which ports have high or low priority traffic
Description
Insert VLAN Tags: If specified, will add VLAN tags to frames without existing tags
Strip VLAN Tags: If specified, will remove VLAN tags from frames if they exist
VLAN Enforcement: Allows unicast frames to adhere or ignore the VLAN configuration
VLAN Mask Registers: Allows configuration of individual VLAN grouping.
VLAN Tag Insertion Values: Specifies the VLAN tag to be inserted if enabled (see above)
Description
Station MAC Address: Used as source address for MAC control frames as used in full
duplex flow control mechanisms.
Table 3. Priority Control
Table 4. VLAN Control
Table 5. Misc. Control
27
KS8999
Micrel

Related parts for KS8999