KS8995MI Micrel Inc, KS8995MI Datasheet - Page 59

IC SWITCH 10/100 5PORT 128PQFP

KS8995MI

Manufacturer Part Number
KS8995MI
Description
IC SWITCH 10/100 5PORT 128PQFP
Manufacturer
Micrel Inc
Datasheets

Specifications of KS8995MI

Applications
*
Mounting Type
Surface Mount
Package / Case
128-MQFP, 128-PQFP
Number Of Primary Switch Ports
5
Internal Memory Buffer Size
64
Operating Supply Voltage (typ)
1.8/2.5/3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII/SNI
Power Supply Type
Analog/Digital
Package Type
PQFP
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
128
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
1.9/2.6/3.6V
Operating Supply Voltage (min)
1.7/2.4/3V
Operating Temperature Classification
Industrial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
576-1017 - BOARD EVAL EXPERIMENT KS8995M
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
576-1020

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KS8995MI
Manufacturer:
Micrel Inc
Quantity:
10 000
(2) MIB counter read (read port 2 rx 64 counter)
(3) MIB counter read (read port 1 tx drop packets)
Note:
To read out all the counters, the best performance over the SPI bus is (160+3) × 8 × 200 = 260ms, where there are 160 register, 3 overhead, 8 clocks
per access, at 5MHz. In the heaviest condition, the byte counter will overflow in 2 minutes. It is recommended that the software read all the counters at
least every 30 seconds. The per port MIB counters are designed as “read clear.” A per port MIB counter will be cleared after it is accessed. All port
dropped packet MIB counters are not cleared after they are accessed. The application needs to keep track of overflow and valid conditions on these
counters.
June 2009
KS8995M
Write to reg110 with 0x1c
(read MIB counter selected)
Write to reg111 with 0x2e
(trigger the read operation )
Then
Read reg117 (counter value 31-24)
// If bit 31 = 1, there was a counter overflow.
// If bit 30 = 0, restart (reread) from this register.
Read reg118 (counter value 23-16)
Read reg119 (counter value 15-8)
Read reg120 (counter value 7-0)
Write to reg 110 with 0x1d
Write to reg 111 with 0x00
Then
Read reg119 (counter value 15-8)
Read reg120 (counter value 7-0)
59
M9999-062309
Micrel, Inc.

Related parts for KS8995MI