HCPL-5760#200 Avago Technologies US Inc., HCPL-5760#200 Datasheet
HCPL-5760#200
Specifications of HCPL-5760#200
Available stocks
Related parts for HCPL-5760#200
HCPL-5760#200 Summary of contents
Page 1
... Hermetically sealed 8-pin dual in-line packages • Performance guaranteed over - +125 C • input • Programmable sense voltage • Hysteresis • HCPL-3700 operating compatibility • Logic compatible output • 1500 Vdc withstand test voltage • Thresholds guaranteed over temperature • Thresholds independent of LED characteristics Applications • ...
Page 2
... These units combine several unique functions in a single package, providing the user with an ideal component for computer input boards and other applica- HCPL-5760 HCPL-5761 HCPL-576K Gold Option #200 Option #100 Option #300 Option #600 5962- 8947701PX 8947701PC ...
Page 3
Absolute Maximum Ratings Storage Temperature Range ............................................. - +150 C Operating Temperature ....................................................... - 125 C Lead Solder Temperature .................................................. 260 C for 10 s Average Input Current, I .............................................................. Surge Input Current, ...
Page 4
Hermetic Optocoupler Options ;; ;; ; ; ; Option Description 100 Surface mountable hermetic optocoupler with leads trimmed for butt joint assembly. This option is available on commercial and hi-rel product. 0.51 (0.020) MIN. 2.29 (0.090) 2.79 (0.110 ...
Page 5
Electrical Characteristics 125 C, unless otherwise specified. See note 16. A Parameter Symbol I TH+ Input Threshold Current I TH- V TH+ dc (Pins TH- Input Threshold Voltage V TH+ ac (Pins ...
Page 6
Electrical Characteristics 125 Parameter Symbol Propagation Delay Time to Logic Low t PHL Output Level Propagation Delay Time to Logic High t PLH Output Level Logic High Common Mode Transient |CM | ...
Page 7
Typical Characteristics All typical values are at T Parameter Hysteresis Input Clamp Voltage Bridge Diode Forward Voltage Input-Output Resistance Input-Output Capacitance Input Capacitance Output Rise Time (10-90%) Output Fall Time (90-10%) Notes: 1. Maximum operating frequency is defined when output ...
Page 8
... Voltage is Instantaneous Value.) Figure 5. Typical high level supply current, I CCH HCPL-5760/1/K Figure 7. Switching test circuit Figure 4. Typical input current vs. temperature. vs. temperature. Figure 6. Typical propagation delay vs. temperature. Figure 8. Test circuit for common mode transient immunity and typical waveforms. , and low level output voltage HCPL-5760/1/K ...
Page 9
... Figure 11 and determined by Equations (2) and (3). R can provide over-current x transient protection by limiting input current during a transient condition. For monitoring contacts with a relay or switch, the HCPL- 5760/1/K, or 5962-89477 combin- ation with R and R can be used allow a specific current to be con- ducted through the contacts for cleaning purposes (wetting current) ...
Page 10
... Testing consists of 100% screening and quality conformance inspection to MIL-PRF-38534. HCPL-5760/1/K Figure 11. External threshold voltage level selection. For product information and a complete list of distributors, please go to our website: Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies, Pte. in the United States and other countries. ...