SU750XL

Manufacturer Part Number
SU750XL
Description
UPS 750VA 600W 6OUT USB
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
UPSr
Datasheets

Specifications of SU750XL

Power - Rated
750VA / 600W
Ac Outlets
6 (UPS)
Features
DB9 and USB Communications, SNMP Card Slot
Backup Time - Max Load
4 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
6' (1.83m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
13.25" L x 6.75" W x 10.00" H (336.6mm x 171.5mm x 254.0mm)
Weight
29 lbs (13.2kg)
Ac Output Connector
NEMA 5-15R
Brand/series
SmartOnline™
Capacity
750 VA
Color
Black
Communication
DB9, RJ45, RS232, USB
Dimensions
25.4cmH×17.1cmW×33.7cmD
Input Type
NEMA 5-15P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Online, Double Conversion
Output Type
(6) NEMA 5-15R
Power, Rating
600 W
Time, Backup
4 min.
Voltage, Output
120 VAC
Voltage, Supply
600/750 W/VA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Rated input current (at
maximum load)
Nominal Input
Voltage(s) Supported
UPS input connection
type
Input circuit breaker
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended
Electrical Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
6.2A
100V AC; 110V AC; 120V AC
5-15P
15A
10
3
15A 120V
4 min. (600w)
11 min. (300w)
BP24V15RT2U
24
Less than 6 hours from 10% to 90%
RBC24-SUTWR
Battery access door
Hot-swappable, user replaceable batteries
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 150
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 65 (under 70% load only)
14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and
fault status information - includes 4-LED meter display for load and battery charge level
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation
(limit 1);
BP24V28-2U
(limit 1);
BP24V70-3U
(multi-pack compatible)