BATT BACKUP 2.2KVA 120V RACK MNT

SMART2200RMXL2U

Manufacturer Part Number
SMART2200RMXL2U
Description
BATT BACKUP 2.2KVA 120V RACK MNT
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Home/Office, Networkr

Specifications of SMART2200RMXL2U

Rohs Status
Not applicable
Power - Rated
2.2kVA / 1600W
Ac Outlets
8 (UPS)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 20A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA 5-20P
Connector - Ac Output
4 NEMA 5-15R and 4 NEMA 5-15/20R
Weight
64 lbs (29kg)
Ac Output Connector
4 NEMA 5-15R and 4 NEMA 5-15/20R
Brand/series
SmartPro®
Capacity
2200 VA
Color
Black
Communication
DB9, RJ11, RS232, USB
Current, Rating
16 A (Max.) Input⁄1733 W
Dimensions
8.9cmH×44.5cmW×48.26cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-20P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(4) NEMA 5-15R, (4) NEMA 5-15/20R
Power, Rating
1600 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
6 min.
Voltage Regulation
120 V (Sine Wave Output) within ± 5% @ Battery Mode
Voltage, Battery
48 VDC
Voltage, Input
120 V
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
1600/2200 W/VA
Power Rating
2200 VA
Output Voltage Rating
120 V
Number Of Outlets
8
Interface Port
USB
Runtime (full Load)
6 min
Runtime (half Load)
16 min
Topology
Line Interactive
Tower / Rackmount
Rackmount
Size
-
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL288
Rated input current (at
maximum load)
Nominal Input Voltage(s)
Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical
Service
BATTERY
Full load runtime (minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
13.3A (120V), 14.6A (110V), 16.0A (100V)
120V AC
5-20P
20A
10
3
20A 120V
6 min. (1600w)
16 min. (800w)
Extended runtime supported via optional external battery packs
BP48V24-2U
48
Less than 4.5 hours from 10% to 90%
RBC94-2U
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79 to 147
Voltage reduction of 12% applies when input is between 127 and 145 (120V), 116 and 133 (110V), 106 and
121 (100V)
Voltage boost of 12% applies when input voltage is between 96 and 108 (120V), 87 and 99 (110V), 83 and 90
(100V)
Voltage boost of 24% applies when input voltage is between 83 and 95 (120V only)
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches
support nominal voltage selection
(limit 1); BP48V60RT3U (multi-pack compatible)