NHD-C160100DIZ-FSW-FBW Newhaven Display, NHD-C160100DIZ-FSW-FBW Datasheet - Page 15

LCD COG GRAPH 160X100 WH TRANSFL

NHD-C160100DIZ-FSW-FBW

Manufacturer Part Number
NHD-C160100DIZ-FSW-FBW
Description
LCD COG GRAPH 160X100 WH TRANSFL
Manufacturer
Newhaven Display
Series
NHD-C160100DIZ-Fr
Datasheet

Specifications of NHD-C160100DIZ-FSW-FBW

Display Type
LCD
Display Mode
Transflective
Viewing Area
46.2mm L x 33.89mm W
Backlight
LED - White
Dot Size
0.23mm W x 0.23mm H
Dot Pitch
0.25mm x 0.25mm
Dot Pixels
160 x 100
Interface
Serial
Pixel Density
160 x 100
Fluid Type
FSTN Positive
Module Size (w X H X T)
49.2 mm x 47.6 mm x 4 mm
Viewing Area (w X H)
46.2 mm x 33.89 mm
Backlighting
Side LED White
Operating Temperature Range
- 20 C to + 70 C
Attached Touch Screen
No
Product
COG LCD Module
Style
COG LCD Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Quality Information
High Temperature storage
Low Temperature storage
High Temperature
Operation
Low Temperature
Operation
High Temperature /
Humidity Operation
Thermal Shock resistance
Vibration test
Static electricity test
Note 1: No condensation to be observed.
Note 2: Conducted after 4 hours of storage at 25
Note 3:
Precautions for using LCDs/LCMs
See Precautions at
Warranty Information and Terms & Conditions
http://www.newhavendisplay.com/index.php?main_page=terms
Test Item
Test performed on product itself, not inside a container.
www.newhavendisplay.com/specs/precautions.pdf
storage temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the low thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
with high humidity stress for a long time.
Endurance test applying the electric stress
(voltage & current) during a cycle of low
and high thermal stress.
Endurance test applying vibration to
simulate transportation and use.
Endurance test applying electric static
discharge.
Endurance test applying the high
Content of Test
⁰C, 0%RH.
[15]
+80⁰C , 48hrs
-30⁰C , 48hrs
+70⁰C 48hrs
-20⁰C , 48hrs
+40⁰C , 90% RH , 48hrs
-0⁰C,30min -> 25⁰C,5min ->
50⁰C,30min = 1 cycle
10 cycles
10-55Hz , 15mm amplitude.
60 sec in each of 3 directions
X,Y,Z
For 15 minutes
VS=800V, RS=1.5kΩ, CS=100pF
One time
Test Condition
Note
2
1,2
2
1,2
1,2
3

Related parts for NHD-C160100DIZ-FSW-FBW