F-51136NCWHU-FW-AA Optrex America Inc, F-51136NCWHU-FW-AA Datasheet
F-51136NCWHU-FW-AA
Specifications of F-51136NCWHU-FW-AA
Related parts for F-51136NCWHU-FW-AA
F-51136NCWHU-FW-AA Summary of contents
Page 1
... I/O Terminal...........................................................................................11 5. Test..........................................................................................................14 6. Appearance Standards............................................................................15 7. Code System of Production Lot ..........................................................17 8. Type Number..........................................................................................17 9. Applying Precautions .............................................................................17 10. Precautions Relating Product Handling................................................18 11. Warranty..................................................................................................19 Rev. Date F-51136NCWHU-FW-AA (AA) No.2000-0230 First Edition Aug 8, 2000 Final Revision ******** Table of Contents Revision History Page OPTREX CORPORATION OPTREX Approved by Production Div ...
Page 2
... CFL. A security function on CFL heater drive circuit shall be installed in order to turn off the heater automatically when its temperature is being too high. F-51136NCWHU-FW-AA (AA) No.2000-0230 : min. -30℃ ~ max. 85℃ Note 1 : min. -40℃ ~ max. 90℃ : 256×3 [R.G.B] (W) × 64 (H) dots : ...
Page 3
... Hysteresis VH Voltage High Level V OH Output Voltage Low Level V OL Output Voltage High Level V OH Output Voltage Low Level V OL Output Voltage F-51136NCWHU-FW-AA (AA) No.2000-0230 Conditions Min. - -0.3 - -0.3 - -0.3 - -0.3 Conditions Min. - 4.5 - 0.5 V =5.5V 2 ...
Page 4
... Parameter Symbol MCLK f OSC Frequency Supply Current I CC 注 1 = 注1: CC1+ CC2 F-51136NCWHU-FW-AA (AA) No.2000-0230 Conditions Min. - - - =5.0V CC1 =5.0V CC2 SS OPTREX CORPORATION OPTREX Typ. Max. Units - 4. Page 4/19 ...
Page 5
... IORD DB[7:0] WRITE Parameter AB[15:0] and IOCS valid before IOWR↓ AB[15:0] and IOCS hold from IOWR↑ DB[7:0] setup to IOWR↑ DB[7:0] hold from IOWR↑ Pulse width of IOWR AB[15:0] IOCS t 1 IOWR DB[7:0] F-51136NCWHU-FW-AA (AA) No.2000-0230 Symbol Min VALID ...
Page 6
... AB[15:0] and MEMCS hold from MEMWR↑ MEMWR↓ to READY↓ MEMWR↓ to DB[7:0] valid DB[7:0] hold from MEMWR↑ READY negated pluse width AB[15: MEMCS MEMWR Hi-Z READY DB[7:0] Where MCLK=1/fosc or 2/fosc depending on which display mode the chip See Section 2.3.3 ) F-51136NCWHU-FW-AA (AA) No.2000-0230 Symbol ...
Page 7
... Access Time 8-bit Display Memory Interface Display Mode 16-Level Colors 4-Level Colors Black-and-White (BW) F-51136NCWHU-FW-AA (AA) No.2000-0230 Access Time f Access time≦1/ osc-25ns f Access time≦2/ osc-25ns f Access time≦2/ osc-25ns OPTREX CORPORATION OPTREX Page 7/19 ...
Page 8
... Average Life representes the time elapsed at the point of time when the residual ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life mentioned above. N 2.5.Heater Specifications Parameter Heater Voltage Heater Power Resistor Value of Thermistor Resistor Value of Thermistor Constant B F-51136NCWHU-FW-AA (AA) No.2000-0230 Conditions Min. I =5mA 340 L - 4.5 - Ta=25℃ ...
Page 9
... Duty - 1/B Bias ( A : Duty Number Bias Number ). Driving voltage V as the voltage V when the contrast ratio (CR=L O-P V O-P × 〈 ON SIGNAL 〉 F-51136NCWHU-FW-AA (AA) No.2000-0230 Ta=25℃, 1/64 Duty, 1/9 Bias, V Symbol Conditions θ= 0 ゚, φ=-゚ CR - x - Ta=25℃ ...
Page 10
... Duty, 1/9 Bias ゚ 135 ゚ 180 ゚ 225 ゚ 270 ゚ ・Area shows typ. CR≧10 3.3.System Block Diagram Photometer #1980A WB Computer F-51136NCWHU-FW-AA (AA) No.2000-0230 f =17.7V, =140Hz ゚ φ (φ= 0 ゚) θ 180 ゚ 315 ゚ 270 ゚ ...
Page 11
... AB12 29 AB13 30 AB14 31 AB15 32 DB0 33 DB1 34 DB2 35 F-51136NCWHU-FW-AA (AA) No.2000-0230 Level - Frame Ground ― Power Supply (0V, GND) ― Power Supply (0V, GND) ― Power Supply for Logic ― Power Supply for Logic ― Power Supply for LCD Drive ― Power Supply for LCD Drive ― ...
Page 12
... TH2 3 +12V 4 GND 4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. MODULE F-51136NCWHU-FW-AA (AA) No.2000-0230 Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Level - ...
Page 13
... MPUCLK SED 1353 RESET AB0~AB15 DB0~DB7 8 15 VCC1 VSS DC/DC Converter VCC2 VCONT HV GND TH1 TH2 +12V GND F-51136NCWHU-FW-AA (AA) No.2000-0230 Row Driver YD LH1532 × LCDENB XSCL 4 D0~D3 3 VCS0,VWE,VOE VA0~VA14 256K S-RAM VD0~VD7 To LSI To LSI Temp.Comp & ...
Page 14
... Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting container. F-51136NCWHU-FW-AA (AA) No.2000-0230 Conditions 85℃±2℃, 96hrs (operation state) -30℃±2℃, 96hrs (operation state) 90℃ ...
Page 15
... All directions for inspecting the sample should be within 45 ゚ against perpendicular line. 6.2.Definition of applicable Zones A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area F-51136NCWHU-FW-AA (AA) No.2000-0230 45 ゚ A Zone Bezel Flame B Zone C Zone ...
Page 16
... The Shape of Dot 4 Polarizer Scratches 5 Polarizer Dirts 6 Complex Foreign Substance Defects 7 Distance between Different Foreign Substance Defects F-51136NCWHU-FW-AA (AA) No.2000-0230 Criteria (1) Round Shape Zone Dimension (mm) D ≦0.1 0.1 < D ≦0.2 0.2 < D ≦0.3 0.3 < D ≦0.35 0.35< Long + Short ) / Disregard (2) Line Shape ...
Page 17
... The type number of module is specified on the back of module as follows. F-51136NCWHU-FW-AA 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. F-51136NCWHU-FW-AA (AA) No.2000-0230 □ □ □ ...
Page 18
... Care should be taken not to touch connection areas to avoid burns. ② Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. ③The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. F-51136NCWHU-FW-AA (AA) No.2000-0230 OPTREX CORPORATION OPTREX Page 18/19 ...
Page 19
... Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later. F-51136NCWHU-FW-AA (AA) No.2000-0230 OPTREX CORPORATION OPTREX ...