CU24043-Y100 Noritake Company Inc, CU24043-Y100 Datasheet

MODULE VF DISPLAY 24X4 5V CHAR

CU24043-Y100

Manufacturer Part Number
CU24043-Y100
Description
MODULE VF DISPLAY 24X4 5V CHAR
Manufacturer
Noritake Company Inc
Datasheets

Specifications of CU24043-Y100

Outline L X W X H
116.00mm x 37.00mm
Viewing Area
73.40mm L x 14.95mm W
Display Format
24 x 4
Display Type
Character
Format
5 x 8 Dots
Voltage - Supply
5V
Character Size
2.10mm H x 3.34mm W
Interface
Parallel/Serial
Operating Temperature
-40°C ~ 85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Dots
-
Other names
286-1072
This product complies with RoHS Directive 2002/95/EC
Specification No:
Date of Issue:
Revision:
This specification is subject to change without prior notice.
Vacuum Fluorescent Display
Model: CU24043-Y100
NORITAKE ITRON CORP. / Japan
http://www.noritake-itron.jp
Specification
Module
Published by
DS-1570-0001-00
January 29, 2009 (00)
RoHS 2002/95/EC

Related parts for CU24043-Y100

CU24043-Y100 Summary of contents

Page 1

... Vacuum Fluorescent Display Specification Model: CU24043-Y100 Specification No: Date of Issue: Revision: NORITAKE ITRON CORP. / Japan http://www.noritake-itron.jp This specification is subject to change without prior notice. This product complies with RoHS Directive 2002/95/EC RoHS 2002/95/EC Module DS-1570-0001-00 January 29, 2009 (00) Published by ...

Page 2

... Font Table Configuration ................................................................................................................. 14 11 Display Area-End of Line Behavior ............................................................................................... 15 12 Initial setting........................................................................................................................................ 17 13 Commands........................................................................................................................................... 17 13.1 Command Configuration ............................................................................................................. 17 13.2 Command Set ............................................................................................................................... 18 13.3 Detail of Command Set ............................................................................................................... 19 13.3.1 Character display .................................................................................................................... 19 13.3.2 Back Space.............................................................................................................................. 20 13.3.3 Horizontal Tab......................................................................................................................... 20 13.3.4 Line Feed ................................................................................................................................ 21 13.3.5 Home Position......................................................................................................................... 21 13.3.6 Display Clear .......................................................................................................................... CU24043-Y100 ...

Page 3

... Font Magnification.................................................................................................................. 36 13.3.49 Individual Character Brightness Level Setting ....................................................................... 37 14 Pin Configuration ............................................................................................................................... 38 14.1 Parallel interface connecter (Fourteen through-holes / CN1)................................................ 38 14.2 Serial interface connector (Six through-holes / CN3) ............................................................. 38 15 Firmware Version Notation .............................................................................................................. 38 16 Physical Dimensions......................................................................................................................... 39 Notice for the Cautious Handling VFD Modules .................................................................................... 40 Revision Note.................................................................................................................................................. CU24043-Y100 ...

Page 4

... General Description 1.1 Scope This specification covers the operation and operating requirements of the Vacuum Fluorescent Display (VFD) module CU24043-Y100. 1.2 Features • Functions Character highlight o Easy to use ASCII commands and fonts. o Character Magnification o Screen Saver o Blink Action Command(Display or Character) o • Display ...

Page 5

... Controller Firmware Character font Flash-Memory (User font table) VDD2 DC/DC EF1 Converter EF2 Symbol Min. V −0 −0 −20.0 IN Symbol Min CU24043-Y100 VFD Jumper Swiitch Note: Flash memory re-write rating is approximately 10,000 times. Typ. Max. Unit +20.0 DC Typ. Max. Unit V 5 ...

Page 6

... IL3 V V 0.8× IH1 CC V SIN 3.0 IH2 V - OL1 V 0 OL2 V V −0.1 OH1 CC V 4.0 OH2 I - 220 -1 CC1 190 CC2 280 CC1 I - 220 -2 CC2 CC3 - 1 1 CU24043-Y100 = 5 Max. Unit Condition V - −0. 5.0 µ 0.25 µ KOhm 0.2× 0 0 +15 ...

Page 7

... Y) 2 × Y) 3.1 mm 3.87 mm 0. × Y) 0. × Y) Approximately 48 g TT-99-3102 TT-98-3413 Asynchronous Serial Interface SIN Y series Host Display System Module SBUSY - 6 - CU24043-Y100 2 (100% brightness) Y series Display Module ...

Page 8

... During data execution, the parallel busy line is high (PBUSY=1). Writing data when PBUSY = 1 causes data loss, so please write data when PBUSY = 0. 7.1.2 Flowchart Start to send data PBUSY = 0? Set D0-D7 Wait (Min. 20uS) Continue to send data ? NO YES / / YES End - 7 - CU24043-Y100 ...

Page 9

... Interface Timing 1 /WR 0 Min. 50ns 1 D0- PBUSY 0 Note: Monitoring the parallel busy line (PBUSY) is strongly recommended, because it prevents data loss and minimizes a waiting time to write next data. Please write data when PBUSY = 0. Min. 100ns Max. 40ns - 8 - CU24043-Y100 Min. 20000ns Min. 0ns ...

Page 10

... SBUSY 1 -> 0 Writing data when SBUSY = 1 may cause data loss, so please write data when SBUSY = 0. 7.2.2 Flowchart Remaining space of receiving buffer 16 byte or less 24 byte or more Start to send data SBUSY = 0? YES Send one byte data Continue to send data ? YES - 9 - CU24043-Y100 NO NO End ...

Page 11

... Max. 30μs 9,600 ~ 115,200bps (Selectable by Jumper) Default: 38,400bps None Start (1bit)+Data (8bit)+Stop (1bit) SBUSY Min. Min. 0μs 20μs 9,600 ~ 115,200bps (Selectable by Jumper) Default: 38,400bps None Start (1bit)+Data (8bit)+Stop (1bit) None - 10 - CU24043-Y100 Min. 0μs Min. 0μs ...

Page 12

... Reset Timing Reset pulse (active low) should be longer than 1ms. The module sets the SBUSY/PBUSY line upon receipt of Reset signal and clears the line when ready to receive data. /RESET PBUSY SBUSY SIN /WR Min. 1ms Max. 100ms Min. 0μs Min. 0μ CU24043-Y100 ...

Page 13

... Baud Rate Setting (for Asynchronous Serial Interface only) 38,400bps (Default) 19,200bps 9,600bps 115,200bps 8.1.2 Test Mode Refer to “9.4 Test mode”. Components side J2 Baud Rate J0 OPEN SHORT OPEN SHORT Mode JT Direct Command OPEN Mode (Default) Test Mode SHORT - 12 - CU24043-Y100 BT* JT CN1 CN3 J1 OPEN OEPN SHORT SHORT ...

Page 14

... The module accepts only two commands: “13.3.42 Read status information” and “13.3.45 Serial OUT mode end”. 9.4 Test mode The module does not accept any commands but displays test-patterns. Test purpose only. OPEN Initial State SHORT NO Test Mode - 13 - CU24043-Y100 Direct Commnad Mode Asynchronous Serial Interface S YE Serial OUT Mode User Set up Mode ...

Page 15

... This display's Font Table (20h-FFh) is configured as follows. The configuration can be changed by command. The Font Table used in the default state is as follows. 13.3.20 Specify International font set 1Bh 52h n For font pattern details, refer to font spec. DS-1519-0002-xx. 13.3.30 Specify character code type 1Bh 74h CU24043-Y100 ...

Page 16

... Current Cursor Position It is possible to display regular size (1×1) characters in the dead space. Current Cursor Position Current Cursor Position - 15 - CU24043-Y100 Right Most Column Lower Most Row Right Most Column Lower Most Row Right Most Column Lower Most Row Dead Space ...

Page 17

... The next cursor position is here. The next 2×2 magnified character is displayed here possible to display a regular size (1×1) characrer in the dead space. Current Cursor Position Right Most Column Current Cursor Position - 16 - CU24043-Y100 Right Most Column Lower Most Row Dead Space Lower Most Row ...

Page 18

... Re-loaded Not re-loaded Re-loaded Not re-loaded Control command ESC command User Setup command ― Action command ― Operation mode-related command ― Character-related command Character code - 17 - CU24043-Y100 External reset or "User set up "Reset" mode end" command command Disable America 100% 40h Cleared Stopped ...

Page 19

... CU24043-Y100 - - - - - - - - - - [x1 d1…d(a X x1)]… [xk d1…d(a X xk)] c - - - - ...

Page 20

... Display a character on the current cursor position Move to Scroll ON mode. Note: The cursor does not move. 1. Shift only the current row left by one column to make a space for the next character. 2. Display a character on the space Note: The cursor does not move CU24043-Y100 Operations Operations Operations Operations ...

Page 21

... Move the cursor to left most column of next lower Excluding lower most row row. 1. Clear upper most row. 2. Shift all rows up by one to make lower most row Lower most row clear. 3. Move the cursor to left most column of lower most row CU24043-Y100 Operations No operation Operations No operation Operations Operations ...

Page 22

... Move the cursor to the same column of next lower Excluding lower most row row. 1. Clear upper most row. 2. Shift all rows up by one to make lower most row Lower most row clear. Note: The cursor does not move. Y direction (Row CU24043-Y100 Operations Operations Operations Operations No operation ...

Page 23

... Cursor position y Lower byte (1 line /unit) Definable area: 0 (00h) ≦ xL ≦ 23 (17h) 0 (00h) ≦ yL ≦ 3 (03h) Function: The cursor moves to the specified X, Y position. If the specified X, Y position (X, Y, either or both) is outside the definable area, the command is ignored, and the cursor remains in the same position CU24043-Y100 ...

Page 24

... CU24043-Y100 16h 17h □□□□□ □□□□□ □□□□□ ...

Page 25

... P28 P29 P30 P33 P34 P35 P38 P39 P40 B7(MSB P16 P15 P14 P24 P23 P22 P32 P31 P30 P40 P39 P38 - 24 - CU24043-Y100 B0(LSB P13 P12 P11 P10 P21 P20 P19 P18 P29 P28 P27 P26 P37 P36 P35 P34 P1 P9 ...

Page 26

... Note: Within this mode, continuous high speed data write may cause display to flicker. Blinking speed may deviate from set speed. The figure in 13.3.21 Specify flickerless write mode shows the difference between Flickerless Mode and Quick Write Mode CU24043-Y100 ...

Page 27

... Quick Write Mode Screen Refreshing Command/data processing Command/ Command/Data 1 Data Comma nd/ Command/ Command/Data 1 Data CU24043-Y100 n Font set 00h America 01h France 02h Germany 03h England 04h Denmark 1 05h Sweden 06h Italy 07h Spain1 08h Japan 09h Norway 0Ah Denmark2 0Bh ...

Page 28

... Function: Characters from cursor position to right end of same line move to the right by one character. The right-most character is discarded. One-character blank (space) is set at cursor position. Cursor does not move. Command is ignored if there is insufficient space in the x and/or y direction for one character at the current cursor position CU24043-Y100 ...

Page 29

... FFh - 28 - CU24043-Y100 Font code type PC437(USA – Euro std) Katakana – Japanese PC850 (Multilingual) PC860 (Portuguese) PC863 (Canadian-French) PC865 (Nordic) WPC1252 PC866 (Cyrillic #2) PC852 (Latin 2) PC858 FROM User font table ...

Page 30

... Brightness level setting Definable area: 1 (01h) ≦ n ≦ 8 (08h)、49 (31h) ≦ n ≦ 56 (38h) Default (04h) Function: Specify display brightness level. If n=0 is specified, scrolling is appeared by character n 00h 01h – 1Fh - 29 - CU24043-Y100 Speed Instantaneous n×13.5ms (Typ.) n Brightness level 01h or 31h 25 % 02h or 32h 50 % 03h or 33h ...

Page 31

... During display blinking, Block cursor, Underline cursor blink and Character blink stops. After blink action, blinking speed for Block cursor, Underline cursor blink and Character blink change to t1 and t2 as set in blink action command. p=0: A display is not affected. p=1: Repeat blink display with normal and blank display - 30 - CU24043-Y100 ...

Page 32

... Jumper settings are re-loaded; baud rate (for asynchronous serial), and test mode setting. p=00h or 30h: Power OFF (display OFF, Power save mode) p=01h or 31h: Power ON (display ON) p=02h or 32h: All dots OFF p=03h or 33h: All dots CU24043-Y100 ...

Page 33

... P40 B7(MSB P16 P15 P14 P13 P24 P23 P22 P21 P32 P31 P30 P29 P40 P39 P38 P37 - 32 - CU24043-Y100 5 Bytes / font x 224 characters (1120 bytes B0(LSB P12 P11 P10 P9 P20 P19 P18 P17 P28 P27 P26 P25 P36 P35 P34 P33 ...

Page 34

... User font information ( are not used) 20h ≦ b ≦ FFh :Character code Hex Number of data 28h 1byte 65h 1byte 40h 1byte 00h~FFh a = 02h : 4 bytes a = 20h : 4 bytes a = 30h : 11 bytes a = 80h : 5 bytes a= 02h : Firmware version a= 20h : Firmware checksum a= 30h : User font table checksum [P(20h-1)…P(FFh-5)] CU24043-Y100 ...

Page 35

... The five characters are displayed in 5×8 font after this command. Characters already displayed are not affected. For details of each pattern, refer to font spec. DS-1519-0002-xx. 5×8 Font 5×7 Font 5×8 Font 5×7 Font d = 80h:Deselect 5×8 Matrix font d = 81h:Select 5×8 Matrix font - 34 - CU24043-Y100 ...

Page 36

... Alternative Magnified font - 35 - CU24043-Y100 ...

Page 37

... Function: Magnify the character by x times on the right, y times downward. This command is valid for characters written after this command execution; it does not affect characters that are already displayed. x=2, y=1 is not supported (command will be ignored). 1x1 magnification (default) 1x2 magnification 2x2 magnification - 36 - CU24043-Y100 ...

Page 38

... Level 3 (29%) 04h or 34h Level 4 (43%) 05h or 35h Level 5 (57%) 06h or 36h Level 6 (71%) 07h or 37h Level 7 (86%) 08h or 38h Level 8 (100 order to set allover the display brightness, please refer to Level 3 Level 4 Level 5 (29%) (43%) (57 CU24043-Y100 Level 6 Level 7 Level 8 (71%) (86%) (100%) ...

Page 39

... D7 Function VCC Power supply SIN Data receive GND Ground SBUSY Display busy NC Non connection /RESET Reset VFD CU24043-Y100 xxxxx Fnnn CN3 Part Number Date Code - 38 - CU24043-Y100 Function Direction Data input Input Data input Input Data input Input Data input Input Data input ...

Page 40

... Physical Dimensions - 39 - CU24043-Y100 ...

Page 41

... If necessary , please ask for assistance from our sales consultant. ・This product is not designed for military, aerospace, medical or other life-critical applications. If you choose to use this product for these applications, please ask us for prior consultation or we cannot take responsibility for problems that may occur CU24043-Y100 ...

Page 42

... Revision Note SPEC number DS-1570-0001-00 Jan.29, 2009 Date Initial Issue - 41 - CU24043-Y100 Revision ...