M0120SD-201MDBR1-1 Newhaven Display, M0120SD-201MDBR1-1 Datasheet - Page 18

no-image

M0120SD-201MDBR1-1

Manufacturer Part Number
M0120SD-201MDBR1-1
Description
MODULE VF CHAR 1X20 4.9MM
Manufacturer
Newhaven Display
Datasheet

Specifications of M0120SD-201MDBR1-1

Outline L X W X H
150.00mm x 32.00mm x 25.50mm
Viewing Area
92.70mm L x 4.90mm W
Display Format
20 x 1
Display Type
Character
Format
5 x 7 Dots
Voltage - Supply
4.5 V ~ 5.5 V
Character Size
4.90mm H x 3.40mm W
Operating Temperature
-20°C ~ 70°C
Product
Character Display Modules
Character Count X Line
20 x 1
Module Size (w X H X T)
150 mm x 32 mm x 25.5 mm
Voltage Rating
4.5 V to 5.5 V
Operating Temperature Range
- 20 C to + 70 C
Dot Format
5 x 7
Viewing Area (w X H)
92.7 mm x 4.9 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Number Of Dots
-
Lead Free Status / Rohs Status
 Details
This instruction
(1) Load a new 60bit address into the address counter (ACC).
(2) Sets the address counter (ACC) to address CG-RAM.
Once “Set CG-RAM Address” has been executed, the contents of the address counter (ACC) will be
automatically modified after every access of CG-RAM, as determined by the “Entry Mode Set” instruction.
wrap around to 00H from 3FH if more than 64 bytes of data are written to CG-RAM
The active width of the address counter (ACC), when it is addressing CG-RAM, is 6-bit, so the counter will
6.2.6.Function Set
This instruction sets width of data bus line.(when to use parallel interface. IM=1). The number of display
line and brightness control.
This instruction initializes the system, and must be the first instruction executed after power-on.
The IF bit selects between an 8-bit or 4-bit bus width interface.
The N bit selects between 1-line or 2-line display.
BR1, BR0 flag is control to brightness of VFD to modulate pulse width of Anode output as follows.
6.2.8 Set DD-RAM Address
6.2.7 Set CG-RAM Address
IF=1: 8-bit CPU interface using DB7 to DB0
IF=0: 4-bit CPU interface using DB7 to DB4
N=1: Select 2 line display (Using anode output A1 to A80)
N=0: Select 1 line display (Using anode output A1 to A40. A41 to A80 fixed Low level.)
DB7 DB6 DB5 DB4
0
0
DB7 DB6 DB5 DB4
DB7 DB6 DB5 DB4
1
RS=0, R/W=0
RS=0, R/W=0
RS=0, R/W=0
0
1
1
BR1
0
0
1
1
IF
DB3 DB2 DB1 DB0
DB3 DB2 DB1 DB0
DB3 DB2 DB1 DB0
ADD
N
BR0
ACG
0
1
0
1
BR1
Brightness
BR2
100%
75%
50%
25%
20H to 3FH
40H to 7FH
80H to A7H (1-Line)
C0H to E7h (2-line)