M0116SD-161SDBR1-S Newhaven Display, M0116SD-161SDBR1-S Datasheet
![MODULE VF CHAR 1X16 5.1MM](/photos/28/27/282711/mfg_m0116sd-161sdbr1-s_sml.jpg)
M0116SD-161SDBR1-S
Specifications of M0116SD-161SDBR1-S
M0116SD-161SDB1-S
Related parts for M0116SD-161SDBR1-S
M0116SD-161SDBR1-S Summary of contents
Page 1
... M0116SD 161SDBR1 S Vacuum Fluorescent Display Module RoHS Compliant nhtech@newhavendisplay.com Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847 844 8795 Fax: 847 844 8796 www.newhavendisplay.com nhsales@newhavendisplay.com ...
Page 2
... This specification applies to VFD module M0116SD-161SDBR1-S. 2.FEATURES 2.1.Construction: Single board display module consists of 16 character (1*16) VFD, VFD controller, DC/DC converter and all necessary control circuitry. 2.2. This module can be controlled by the host with three control signals, SEL, SLK, SDATA. ...
Page 3
Absolute Maximum Ratings Parameter Supply Voltage Input Signal Voltage 3.5. Recommend Operating Conditions(Ta=–10 ~ 70°C unless otherwise noted) 3.6. Pin assignment Symbol Min Tye VCC 0 5 Fig-3. Connector Description Max Unit 7.0 VDC 5.5 VDC ...
Page 4
VFD Grid Assignment And Dimension ...
Page 5
Outer Dimensions (Front panel, Structure outline) Fig-5. Outer Dimensions (Structure outline) ...
Page 6
FUNCTION DESCRIPTIONS 4.1. Command Description: There is no 0xF6 function to set digit scan time command undefined sends to the module, there will nothing happens. 4.1.1. Set: display lengh: 4.1.2. Set digit dimmer value: ...
Page 7
Set digit point: 4.1.4. Auto increment mode ON/OFF: ...
Page 8
Display all ON/OFF: 4.1.6. Storing data in UDF: The following 3steps define UDF to RA1~RA8 st The the declaration to degine UDF. (1 byte command) nd The the selection of a UDF character ...
Page 9
Scan Timing Description 4.2.1 Set display length This command sets the display length. For example,if 12digit selected,13~16digita are always OFF. ...
Page 10
Display scan timing T=4.096ms Tdsp=256us Tdig=240us Tblk=16us ...
Page 11
Display Operation 4.2.4.Character Display Operation ...
Page 12
The power on reset function allows the users to re-initialize the display controller, after the power is turned off and then power on. When the controller is initialized, the display status is given below 1. Address of each RAM ...
Page 13
Recommend Initial setting sequence After reset, the module must be set according to the Initial Setting Flowchart shown below. ...
Page 14
Font Table ...