M0220SD-202SDAR1-S Newhaven Display, M0220SD-202SDAR1-S Datasheet - Page 11

MODULE VF CHAR 2X20 5.34MM

M0220SD-202SDAR1-S

Manufacturer Part Number
M0220SD-202SDAR1-S
Description
MODULE VF CHAR 2X20 5.34MM
Manufacturer
Newhaven Display
Datasheet

Specifications of M0220SD-202SDAR1-S

Outline L X W X H
116.00mm x 37.00mm x 11.00mm
Display Format
20 x 2
Display Type
Character
Format
5 x 8 Dots
Voltage - Supply
4.5 V ~ 5.5 V
Character Size
5.34mm H x 2.35mm W
Interface
Parallel/Serial
Operating Temperature
-40°C ~ 85°C
Product
Character Display Modules
Character Count X Line
20 x 2
Module Size (w X H X T)
116 mm x 37 mm x 11 mm
Voltage Rating
4.5 V to 5.5 V
Operating Temperature Range
- 40 C to + 85 C
Dot Format
5 x 8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Viewing Area
-
Number Of Dots
-
Lead Free Status / Rohs Status
 Details
DB7
DB6
DB0
WR/
RD/
RS
3-2. SYNCHRONOUS SERIAL INTERFACE MODE
3-1-2. INTEL I80-TYPE MODE
In the synchronous serial interface mode, instructions and data are sent between the host
and the module using 8-bit bytes. Two bytes are required per read/write cycle and are
transmitted MSB first. The start byte contains 5 high bits, the Read/Write (R/W) control bit,
the Register Select (RS) control bit, and a low bit. The following byte contains the
instruction/data bits. The R/W bit determines whether the cycle is a read (high) or a write
(low) cycle. The RS bit is used to identify the second byte as an instruction (low) or data
(high).
This mode uses the Strobe (STB) control signal, Serial Clock (SCK) input, and Serial I/O
(SI/SO) line to transfer information. In a write cycle, bits are clocked into the module on
the rising edge of SCK. In a read cycle, bits in the start byte are clocked into the module on
the rising edge of SCK. After the minimum wait time, each bit in the instruction/data byte
can be read from the module after each falling edge of SCK. Each read/write cycle begins
on the falling edge of STB and ends on the rising edge. To be a valid read/write cycle, the
STB must go high at the end of the cycle.
This mode uses the Read (RD/) and Write (WR/) control signals to transfer information.
Instructions/data are written to the module on the rising edge of WR/ and are read from
the module after the falling edge of RD/.
Fig. 9. Typical 8-Bit Parallel Interface Sequence Using I80-Type Mode
Write Instruction
IB7
IB6
IB0
Write Instruction
IB7
IB6
IB0
PAGE: 8/19
Read Instruction
BF=“0”
IB6
IB0
Write Data
DB7
DB6
DB0
M0220SD-202SDAR1-S

Related parts for M0220SD-202SDAR1-S