SFH426 OSRAM Opto Semiconductors Inc, SFH426 Datasheet - Page 7

EMITTER IR 880NM R/A SMD

SFH426

Manufacturer Part Number
SFH426
Description
EMITTER IR 880NM R/A SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH426

Current - Dc Forward (if)
100mA
Radiant Intensity (ie) Min @ If
4mW/sr @ 100mA
Wavelength
880nm
Voltage - Forward (vf) Typ
1.5V
Viewing Angle
120°
Orientation
Side View
Mounting Type
Surface Mount
Package / Case
Non-Standard SMD
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1097-2
Q62702P0331

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SFH426
Quantity:
5 237
Part Number:
SFH426 SFH 426 (880NM)
Manufacturer:
perkinElmer
Quantity:
4 136
Part Number:
SFH426-P
Manufacturer:
OSRAM
Quantity:
100 000
Part Number:
SFH426-Z
Manufacturer:
OSRAM/欧司朗
Quantity:
20 000
Löthinweise
Soldering Conditions
Bauform
Types
TOPLED
SIDELED
Zusätzliche Informationen über allgemeine Lötbedingungen erhalten Sie auf Anfrage.
For additional information on general soldering conditions please contact us.
Published by OSRAM Opto Semiconductors GmbH & Co. OHG
Wernerwerkstrasse 2, D-93049 Regensburg
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2002-03-14
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
®
1
, may only be used in life-support devices or systems
Lötbad-
temperatur
Temperature
of the
Soldering
Bath
260 C
260 C
Tauch-, Schwall- und Schlepplötung
Dip, Wave and Drag Soldering
Maximal
zulässige
Lötzeit
Max. Perm.
Soldering
Time
8 s
8 s
7
Abstand
Lötstelle –
Gehäuse
Distance
between
Solder Joint
and Case
2
with the express written approval of OSRAM OS.
Lötzonen-
temperatur
Temperature
of Soldering
Zone
245 C
245 C
Reflow Soldering
Reflowlötung
SFH 421, SFH 426
Maximale
Durchlaufzeit
Max. Transit
Time
10 s
10 s

Related parts for SFH426