LT M673-R1S2-35 OSRAM Opto Semiconductors Inc, LT M673-R1S2-35 Datasheet - Page 16

LED TRUE GRN 528NM CLR SMD

LT M673-R1S2-35

Manufacturer Part Number
LT M673-R1S2-35
Description
LED TRUE GRN 528NM CLR SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr
Datasheet

Specifications of LT M673-R1S2-35

Color
Green
Luminous Flux @ Current - Test
560 mlm
Millicandela Rating
196mcd
Current - Test
10mA
Wavelength - Dominant
529nm
Wavelength - Peak
527nm
Voltage - Forward (vf) Typ
3V
Lens Type
Clear
Lens Style/size
Rectangle, 1.5mm x 1mm
Package / Case
0805 (2012 Metric)
Size / Dimension
2.00mm L x 1.40mm W
Height
1.30mm
Viewing Angle
120°
Mounting Type
Surface Mount
Resistance Tolerance
529nm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1038-2
LTM673R1S235
Q62703Q4897
Published by OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
All typical data and graphs are basing on representative samples, but don’t represent the production range. If requested,
e.g. because of technical improvements, these typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or
system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2003-06-16
Revision History: 2003-06-16
Previous Version: 2003-04-14
Page
4
3
5
8
2
3
16
3
2
4
7
A critical component is a component used in a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
Subjects (major changes since last revision)
value (forward voltage)
power consumption from 85 mW to 80 mW
wavelength groups
diagram max. permissible forward current to OHL01573 and OHL 11574
wavelength grouping for blue, true green and verde
pad size from 16 mm
annotations
reverse voltage (footnote)
new luminous intensity groups for LB M673
values (temperature coefficient of
diagrams max. perm. forward current
1
may only be used in life-support devices or systems
2
to 5 mm
2
dom
16
and V
F
)
2
with the express written approval of OSRAM OS.
LB M673, LV M673, LT M673
2003-03-11
Date of change
2002-07-23
2002-08-21
2003-04-14
2003-06-16

Related parts for LT M673-R1S2-35