LG L890-L1M2-1 OSRAM Opto Semiconductors Inc, LG L890-L1M2-1 Datasheet - Page 15

LED GREEN 570NM 0603 SMD

LG L890-L1M2-1

Manufacturer Part Number
LG L890-L1M2-1
Description
LED GREEN 570NM 0603 SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
SmartLEDr
Datasheet

Specifications of LG L890-L1M2-1

Color
Green
Luminous Flux @ Current - Test
80 mlm
Millicandela Rating
19.6mcd
Current - Test
20mA
Wavelength - Dominant
570nm
Wavelength - Peak
572nm
Voltage - Forward (vf) Typ
2.2V
Lens Type
Diffused
Lens Style/size
Rectangle, 1.3mm x 0.8mm
Package / Case
0603 (1608 Metric)
Size / Dimension
1.70mm L x 0.80mm W
Height
0.65mm
Viewing Angle
160°
Mounting Type
Surface Mount
Resistance Tolerance
570nm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1056-2
LGL890L1M21
Q62703Q6156
Published by OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
All typical data and graphs are basing on representative samples, but don’t represent the production range. If requested,
e.g. because of technical improvements, these typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or
system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2002-12-10
Revision History: 2002-12-10
Previous Version: 2002-11-18
Page
2
12
9
3
3
9
15
3, 4
1, 14
A critical component is a component used in a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
Subjects (major changes since last revision)
changed resin from colorless clear to colorless diffused
recommended solder pad
Package Outlines
pad size from 16 mm
Surge current
Permissible Pulse Handling Capability
annotations
value (reverse voltage from 5 V to 12 V)
tape with 5000/reel and 10000/reel instead of 10000
1
may only be used in life-support devices or systems
2
to 5 mm
2
15
2
with the express written approval of OSRAM OS.
2002-09-18
Date of change
2002-07-23
2002-12-10
LG L890

Related parts for LG L890-L1M2-1