VHB100W-Q24-S5 CUI Inc, VHB100W-Q24-S5 Datasheet
VHB100W-Q24-S5
Specifications of VHB100W-Q24-S5
Related parts for VHB100W-Q24-S5
VHB100W-Q24-S5 Summary of contents
Page 1
... Additionally, high efficiency, fast response, tight regulations, remote sense and remote On/Off control make these converters very useful in many applications. MODEL VHB100W-Q24-S3R3 VHB100W-Q24-S5 VHB100W-Q24-S12 VHB100W-Q24-S15 VHB100W-Q24-S24 VHB100W-Q24-S28 VHB100W-Q24-S48 VHB100W-Q48-S3R3 VHB100W-Q48-S5 VHB100W-Q48-S12 ...
Page 2
... PART NUMBER: VHB100W OUTPUT parameter conditions/description voltage accuracy transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3.3V, 5V 12V& 15V 24V 28V 48V temperature coefficient short circuit protection continuous 5 line regulation 6 load regulation over voltage protection trip range nom. ...
Page 3
... PART NUMBER: VHB100W MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: half-brick dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 page date 05/2009 ...
Page 4
... APPLICATION NOTES 1. OUTPUT DE-RATING The operating case temperature range for VHB100W is -40 ~ +100°C. When operating the VHB100W series, proper derating or cool- ing is needed. The maximum case temperature under any operating condition should not exceed 100°C. Power Dissipated vs Ambient Temperature and Air Flo w Ambient Temperature ,Ta(Deg ...
Page 5
... The fuse rating will depend on the input range and should allow for the maximum current at the lowest input volt- age, as shown in this equation: Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHB100W-Q24-S5, the peak input current at 9V was calculated to be 19. fuse may be suitable for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...
Page 6
... R load R trim-up R (KΩ) is the Where: R o,nom , nominal output voltage Table 1. For example, to trim-up the output voltage of 5.0V is calculated module (VHB100W-Q48-S5 4.6V, R trim-up = 11.2 (KΩ) Ω Ω 3.168 7.2 5.8 8.2 19.656 13.304 25.474 14.76 Table 2 42.33 16.67 48.78 5 ...
Page 7
... PART NUMBER: VHB100W 8. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 100°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...
Page 8
... PART NUMBER: VHB100W 12. OUTPUT SERIES CONNECTIONS Two or more converters can be connected in series to obtain a higher output voltage. To prevent output reverse biasing each other in case of a short, add a Schottky diode on each output in reverse polarity, as shown in the diagram. In the event of a short, the con- verters will forward-bias the diodes and the output reversal will be limited to one diode drop (about 0 ...
Page 9
... PART NUMBER: VHB100W 15. INPUT FILTERING AND EMI INTERFERENCE The VHB100W converters have input capacitors that control input current ripple and the associated EMI interference. However, it has not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...
Page 10
... For proper output ripple and noise measurement, connect a 10μF tantalum and a 1μF ceramic capacitor across the output. Set the scope bandwidth to 20MHz. Probe directly off of one of the capacitors, using a small ground clip to minimize measurement error. +Vin -Vin th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: half-brick dc-dc converter FIGURE 10.3. EMI FILTER FOR VHB100W-XXX-S28 L1 +Vin C2 -Vin C2 47uF/50V KY 47uF/50V KY ...