HBS050ZE-ANT POWER ONE, HBS050ZE-ANT Datasheet

CONV DC-DC 48V IN 3.3V OUT NLT

HBS050ZE-ANT

Manufacturer Part Number
HBS050ZE-ANT
Description
CONV DC-DC 48V IN 3.3V OUT NLT
Manufacturer
POWER ONE
Series
HBS50r
Type
Isolatedr
Datasheet

Specifications of HBS050ZE-ANT

Output
3.3V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
34 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 15A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
80%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
179-2143
Technical Specifications
Description
MCD10037 Rev. 1.0
HBS dc-dc converters provide up to 50 watts of output
power in an industry-standard, half-brick footprint. The
HBS units feature excellent efficiency, Class A conducted
noise specs, and fixed switching frequency. The HBS,
using open-frame packaging, along with planar magnetics
provides maximum useable power with minimal thermal
constraints.
telecom, networking, and industrial applications.
Voltage Range
Reflected Ripple
Input Reverse Voltage Protection
Setpoint Accuracy
Line Regulation V in Min. - V in Max., I out Rated
Load Regulation I out Min. - I out Max., V in Nom.
Remote Sense Headroom
Minimum Output Current
Dynamic Regulation, Loadstep
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I out Rated
OVP Trip Range
OVP
Specifications typically at 25 °C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260 °C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
24 VDC nominal
48 VDC nominal
Pk Deviation
Settling Time
MTBF predictions may vary slightly from model to model.
The HBS Series is especially suited to
Output
Input
Notes
115 - 140% V out Nom.
10%, I out Rated
18 - 36 VDC
34 - 75 VDC
Shunt Diode
±0.2% V out
±0.2% V out
110 - 140%
25% I out
4% V out
0.5 VDC
Page 1 of 3
25 mA
500 μs
Hiccup
Hiccup
±10%
±1%
HBS50 DC-DC Series Data Sheet
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Temperature Coefficient
Case Temperature
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF † (Bellcore TR-NWT-000332)
Safety
Weight (approx.)
Features
• RoHS lead solder exemption compliant
• Industry-standard half-brick
• Open-frame packaging
• 100 °C base plate operation
• Water washable
• “True-trim” option
• 1500 V isolation
• Positive or negative logic
Input - Output
Input - Case
Output - Case
Operating Range
Storage Range
95
90
85
80
75
70
65
60
95
90
85
80
75
70
65
60
10
10
20
20
Efficiency vs. Load (24V Input)
Efficiency vs. Load (48V Input)
30
30
40
40
50-Watt Half-Brick
General
50
LOAD %
50
LOAD %
60
HBS050ZG-A
HBS050ZH-A
HBS050Z10.5-A
60
www.power-one.com
Positive or Negative Logic
HBS050YG-A
HBS050YH-A
HBS050YJ-A
70
70
80
80
5 g, 10 - 55 Hz
-40 to +100 °C
-40 to +125 °C
105 to 115 °C
2.1 x 10 6 hrs
90
V in Negative
1500 VDC
1050 VDC
90
500 VDC
0.2%/°C
500 kHz
UL, cUL
100
10 ms
2.5 oz
100

Related parts for HBS050ZE-ANT

HBS050ZE-ANT Summary of contents

Page 1

Description HBS dc-dc converters provide watts of output power in an industry-standard, half-brick footprint. The HBS units feature excellent efficiency, Class A conducted noise specs, and fixed switching frequency. The HBS, using open-frame packaging, along with planar ...

Page 2

... HBS050YE-A 24 18-36 HBS033YE-A 24 18-36 HBS050YG-A 24 18-36 HBS050YH-A 24 18-36 HBS050YJ-A 24 18-36 HBS050ZE-A 48 34-75 HBS050ZG-A 48 34-75 HBS050ZH-A 48 34-75 HBS050ZJ-A 48 34-75 NOTES: * Maximum input current at minimum input voltage, maximum rated output power nominal rated output. Model numbers highlighted in yellow or shaded are not recommended for new designs. ...

Page 3

Ordering Information Suffix Code Identification: Series Applicability: Features & Options Remote ON/OFF Trim Pin Length Special Options NOTE: Contact factory for availability of specific options. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or ...