MER1S1212SC Murata Power Solutions Inc, MER1S1212SC Datasheet - Page 5

CONV DC/DC 1KVDC TH 1W 12-12V

MER1S1212SC

Manufacturer Part Number
MER1S1212SC
Description
CONV DC/DC 1KVDC TH 1W 12-12V
Manufacturer
Murata Power Solutions Inc
Series
MER1r
Type
Isolatedr
Datasheet

Specifications of MER1S1212SC

Number Of Outputs
1
Output
12V
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
10.8 ~ 13.2V
Package / Case
7-SIP Module (4 Leads)
1st Output
12 VDC @ 84mA
Size / Dimension
0.77" L x 0.24" W x 0.40" H (19.7mm x 6.2mm x 10.2mm)
Power (watts) - Rated
1W
Operating Temperature
-40°C ~ 85°C
Efficiency
88.5%
Approvals
UL
Output Power
1 W
Input Voltage Range
10.8 V to 13.2 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
84 mA
Isolation Voltage
1 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2130-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MER1S1212SC
Manufacturer:
muRataPs
Quantity:
12 000
MER1 Series
1kVDC Isolated 1W Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MER1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MER1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MER1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MER1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85°C and/or case temperature
limit of 130°C (case temperature measured on the face opposite the pins). File number E179522 applies.
The MER1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defi ned below.
MER1S05xxSC: 1A
MER1S12xxSC: 0.375A
MER1S15xxSC: 0.375A
MER1S24xxSC: 0.2A
MER1S48xxSC: 0.1A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
www.murata-ps.com
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
2011/01/24 KDC_MER1.B03 Page 5 of 7

Related parts for MER1S1212SC