HHD20ZGE-N POWER ONE, HHD20ZGE-N Datasheet
HHD20ZGE-N
Specifications of HHD20ZGE-N
Available stocks
Related parts for HHD20ZGE-N
HHD20ZGE-N Summary of contents
Page 1
... LFM forced air without the addition of a heatsink. The outputs also track each other during both startup and shutdown. Model Selection Model Input Voltage Range, VDC HHD20ZGE 36-72 HHD20ZGB 36-72 HHD25ZED 36-72 HHD25ZEB 36-72 ...
Page 2
Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long- term reliability, and cause permanent damage to the converter. Parameter Input voltage Operating Temperature Storage Temperature ON/OFF Control Voltage Environmental and Mechanical ...
Page 3
Output Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Output Voltage Setpoint Accuracy Output Current* Vout1 Output Current* Vout2 Line Regulation Vout1 Line Regulation Vout2 Load Regulation,Vout1,Vout2 Remote Sense Headroom Dynamic ...
Page 4
... Characteristic Curves LOAD % Figure 1. HHD20ZGE Efficiency vs. Output Load LOAD % Figure 2. HHD20ZED Efficiency vs. Output Load LOAD % Figure 3. HHD20ZGB Efficiency vs. Output Load MCD10164 Rev. 1.0, 04-Jun-10 HHD25 DC-DC Series Data Sheet EFF.(36V) 50 EFF.(48V EFF.(75V 100 Figure 4. HHD25ZEB Efficiency vs. Output Load ...
Page 5
... Volts. Table 1. Output 1 Trim Formula Parameter. Model Trim up A HHD20ZGE 2.5 HHD20ZGB 2.5 HHD25ZED 2.047 HHD25ZEB 2.047 Table 2. Trim Formula Parameter. Model Trim up A HHD20ZGE 0.80 HHD20ZGB 2.50 HHD25ZED 6.176 HHD25ZEB 2. Page 20/25A Half-Brick Trim down 3.32 2.5 4 ...
Page 6
The HHD Series converters feature 1500 Volt DC isolation from input to output. The input-to-output resistance is greater than 10MΩ. These converters are provided with Basic insulation between input and output circuits according to all IEC60950 based standards. Nevertheless, if ...
Page 7
... Ambient Temperature (C) Figure 6. HHD20ZGE Derating Curves 100LF 2 M 200LF Ambient Temperature (C) Figure 8. HD20ZGB Derating Curves MCD10164 Rev. 1.0, 04-Jun-10 HHD25 DC-DC Series Data Sheet 100LFM 4 200LFM 300LFM 2 400LFM Ambient Temperature (C) Figure 7. HHD25ZED Derating Curves 100LFM 200LFM 300LFM ...
Page 8
Mechanical Drawing Ordering Information Options Suffixes to add to part number Remote On/Off Positive- Standard, no suffix required Negative- Add “N” suffix Pin Length 0.18”- Standard, no suffix required 0.11”- Add “8” suffix 0.15”- Add “9” suffix Notes 1. Consult ...