CC30-2405SFH-E TDK Corporation, CC30-2405SFH-E Datasheet - Page 5

CONV DC/DC 24V 5V 6A 30W PCB

CC30-2405SFH-E

Manufacturer Part Number
CC30-2405SFH-E
Description
CONV DC/DC 24V 5V 6A 30W PCB
Manufacturer
TDK Corporation
Series
CC-P-Er
Type
Isolatedr

Specifications of CC30-2405SFH-E

Output
5V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
24V
Package / Case
20-DIP Module (17 Leads)
1st Output
5 VDC @ 6A
Size / Dimension
1.51" L x 1.32" W x 0.33" H (38.4mm x 33.5mm x 8.3mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 85°C
Efficiency
89%
Approvals
CSA, cUL, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
30W
Output Voltage
5V
Output Current
6A
Approval Bodies
CULus, CSA
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
4. Terminal Function / Protection Function / Series
4. Terminal Function / Protection Function / Series Connection
4-1 Remote Control (RC Terminal)
When a connection method as shown in Fig. 4-1-1 is used, and if capacitance exists between the +Vin and RC terminals, there is
the possibility of the RC terminal voltage becoming unstable because of the capacitance in the case when the input voltage is
changed suddenly (it becomes a factor causing malfunction). In that case, we recommend the connection method shown in Fig.
4-1-2. In addition, the rating of the external transistor used is as follows: Vce: greater than the Vin, Ic: minimum 10mA.
※Contact TDK-Lambda concerning items not mentioned or items which are not clear.
4. Terminal Function / Protection Function / Series
4. Terminal Function / Protection Function / Series
When the input voltage is in an ON condition, the RC terminal can be used to control output ON/OFF.
When not using the Remote Control function, either open the RC terminal or connect it to the –Vin terminal.
We recommend connection to the –Vin terminal in order to prevent malfunction caused by noise.
Input
If the RC terminal is set at L Level or open condition, the output is ON.
If the RC terminal is set at H Level, the output is OFF.
When the converter is in a latch stop condition because of a protection function, after removing the abnormal factor, use the
Remote Control to turn the output OFF, then turn ON after the lapse of 1 second minimum for recovery to occur.
DC
Fig. 4-1-1 RC Terminal Connection Method 1
Control
Signal
RC
Table 4-1-2 Recommended Value of External Resistor R1 when using the RC Terminal
H Level
L Level
R1 Recommended Value
Logic
Converter Type
R2 (Typical)
R3 (Typical)
+Vin
-Vin
RC
Table 4-1-1 RC Terminal Specifications
R3
R2
Qrc
Min. [V]
10
0
RC Terminal Voltage
CCxx-24xxSxx-E
or Open
91kΩ
22kΩ
15kΩ
※ When the –Vin terminal is used for GND.
Connection
Connection・ ・ ・ ・ Parallel Connection
Connection
Fig. 4-1-2 RC Terminal Connection Method 2
Input
Max. [V]
DC
+Vin
1.2
Control
Signal
CCxx-48xxSxx-E
RC
Parallel Connection
Parallel Connection
Parallel Connection
194kΩ
220kΩ
47kΩ
R1
Output Condition
OFF
ON
-Vin
+Vin
RC
R2
R3
Qrc

Related parts for CC30-2405SFH-E