... Model Selection Model Input Voltage Current, VDC HBC25ZH 36-75 Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10036 Rev. 1.0 HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters Features ...
Page 2
Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-term reliability, and cause permanent damage to the converter. Parameter Input voltage Operating Temperature Storage Temperature ON/OFF Control Voltage Environmental and Mechanical Specifications ...
Page 3
Output Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Output Voltage Setpoint Accuracy Output Current* Line Regulation Load Regulation Total output voltage regulation Remote Sense Headroom Dynamic Regulation Peak Deviation Settling ...
Page 4
... Efficiency Curves LOAD % Figure 1. HBC25ZH Efficiency vs. Output Load Typical Application Figure 2 shows the recommended connections for the HBC Series converter. HBC25ZH Fuse +Vi +Sense C1 Trim On/Off -Sense -Vi Figure 2. Typical Application of HBC Series The HBC Series converters do not require any external components for proper operation. ...
Page 5
Figure 3. HBC Series Positive Trim Schematic The equations below determine the trim resistor value required to achieve a V change in the output voltage. ( 100 %) ( 100 Rup . 1 225 % % 100 ...
Page 6
... NC ( LFM Figure 4. HBC25ZH-T, NT Derating Curves For example, from Figure 4, the HBC25ZH operating at 45 ºC can deliver reliably with 200 LFM forced air, while reliably with 400 LFM forced air. Page THERMAL DERATING CURVE HBC25ZH-T, -NT Vin = 54V, Orientation : Vin- to Vin + ...
Page 7
... Ordering Information Options Remote ON/OFF Trim Pin Length Example: HBC25ZH- positive on/off logic, industry standard Trim output converter with 0.110” pin length Notes 1. Consult factory for the complete list of available options. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc ...