24H1601-2R POWER ONE, 24H1601-2R Datasheet

no-image

24H1601-2R

Manufacturer Part Number
24H1601-2R
Description
CONV DC-DC 50W 24VDC CASSETTE
Manufacturer
POWER ONE
Series
Hr
Type
Isolatedr
Datasheet

Specifications of 24H1601-2R

Output
24V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Surface Mount
Voltage - Input
14 ~ 30V
Package / Case
Module
1st Output
24 VDC @ 2A
Size / Dimension
6.63" L x 4.38" W x 1.52" H (168.5mm x 111.2mm x 38.7mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 50°C
Efficiency
83%
Approvals
CE, cUL, TUV, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
Q1166581
Table of Contents
Description ....................................................................... 1
Model Selection ............................................................... 2
Part Number Description and Product Marking ............... 2
Functional Description ..................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 5
Auxiliary Functions ........................................................... 8
REV. MAR 27, 2006
Description
The H series of DC-DC converters represents a broad and
flexible range of cassette power supplies for use in
advanced electronic systems. Features include high
efficiency, reliability, and reasonable output voltage noise.
The converter inputs are protected against surges and
transients occuring at the source lines. Input over- and
undervoltage cut-out circuitry disables the outputs if the
input voltage is outside the specified range.
All outputs are open- and short-circuit proof and are
protected against overvoltages by means of built-in
suppressor diodes. The outputs can be inhibited by a logic
signal applied to the connector pin 2 (i). If the inhibit
function is not used, pin 2 should be connected to pin 23 to
enable the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case, and
output-to-output isolation is provided. The converters are
designed and built according to the international safety
standard IEC/EN 60950 and have been approved by the
39
1.54"
8TE
168
6.6"
111
4.37"
3U
Page
Page 1 of 19
Features
safety agencies TÜV and UL (USA and Canada).
The case design allows operation at nominal load up to
50 °C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 50 °C, but
the case temperature should remain below 80 °C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature T
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to
individual applications.
The converters may either be plugged into 19-inch rack
systems according to DIN 41494, or be chassis mounted.
Electromagnetic Compatibility (EMC) ............................ 10
Mechanical Data ............................................................ 11
Immunity to Environmental Conditions ........................... 12
Safety and Installation Instructions ................................ 12
Description of Options .................................................... 15
Accessories .................................................................... 19
• Wide input voltage range suitable for battery operation
• Efficient input filter and built-in surge and transient
• Outputs individually isolated
• Outputs fully protected against overload
Safety according to IEC/EN 60950
Wide input voltage ranges up to 60 VDC
1, 2, or 3 outputs up to 48 VDC
Class I equipment
50 Watt DC-DC Cassette Converters
suppression circuitry
H Series Data Sheet
www.power-one.com
C
exceeds the
Page

Related parts for 24H1601-2R

24H1601-2R Summary of contents

Page 1

Description The H series of DC-DC converters represents a broad and flexible range of cassette power supplies for use in advanced electronic systems. Features include high efficiency, reliability, and reasonable output voltage noise. The converter inputs are ...

Page 2

... REV. MAR 27, 2006 50 Watt DC-DC Cassette Converters Input Voltage Range and Efficiency η nom i min max min 2 [ VDC [%] VDC - 12H1001- 12H1301-2R 79 24H1301-2R - 12H1501-2R 80 24H1501-2R - 12H1601-2R 81 24H1601- 12H1901-2R 83 24H1901-2R - 12H2320-2 79 24H2320-2 - 12H2540-2 80 24H2540-2 0.7 12H3020-2 77 24H3020-2 0.6 12H3040-2 77 24H3040 VDC ............. 12 5.1 V ............... ............... ............... ............... ............... ............. ............. 40 ...

Page 3

Functional Description The input voltage is fed via an input filter to the input capacitor. This capacitor sources a single-transistor forward converter. Each output is powered by a separate secondary winding of the main transformer. The resultant voltages are rectified ...

Page 4

Electrical Input Data General conditions: – °C, unless T is specified – Connector pins 2 and 23 interconnected, R input not connected. Table 2: Input data Input Characteristics Conditions V Operating input voltage I = ...

Page 5

Electrical Output Data General conditions – °C, unless T is specified – Connector pins 2 and 23 interconnected, R input not connected. Table 4a: Output data Output Characteristics Conditions V Output voltage ...

Page 6

Output Protection Each output is protected against overvoltages which could occur due to a failure of the internal control circuit. Voltage suppressor diodes (which under worst case condition may become a short circuit) provide the required protection. The suppressor diodes ...

Page 7

Thermal Considerations If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature T (see table: Temperature specifications) A max and is operated at its nominal input voltage and output power, the temperature measured ...

Page 8

Auxiliary Functions i Inhibit for Remote On and Off Note: With open i input: Output is disabled ( V The outputs of the module may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between ...

Page 9

Table 7a: R for V < V (conditions nom nom o nom V [V] R [kΩ 0.5 0.432 2.0 1.0 0.976 3.0 1.5 1.65 4.0 ...

Page 10

Electromagnetic Compatibility (EMC) A suppressor diode together with an input filter form an effective protection against input transient voltages which typically occur in most installations, but especially in Electromagnetic Immunity Table 8: Immunity type tests 1 Phenomenon Standard Level Electrostatic ...

Page 11

Mechanical Data Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated. 100 (11.6) 94.5 17.25 12.17 7. (LED green) Inhibit i (LED red) Potentiometer (option Fig. 12 DC-DC converter in case H02, weight 770 g ...

Page 12

Immunity to Environmental Conditions Table 10: Mechanical stress Test method Standard Ca Damp heat IEC/DIN IEC 60068-2-3 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN/DIN EN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN/DIN EN 60068-2-29 (half-sinusoidal) MIL-STD-810D section 516.3 ...

Page 13

Installation Instructions The H series DC-DC converters are components, intended exclusively for inclusion within other equipment by an industrial assembly operation or by professional installers. Installation must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, ...

Page 14

Safety of operator accessible output circuit If the output circuit of a DC-DC converter is operator accessible, it shall be a SELV circuit according to the IEC/ EN 60950 related safety standards. Since the H series DC-DC converters provide double ...

Page 15

Description of Options Table 16: Survey of options Option Function of Option -7 Extended operational ambient temperature range 1 D Input and/or output undervoltage monitoring circuitry Input and output undervoltage monitoring circuitry 1 Option D excludes option ...

Page 16

Threshold tolerances and hysteresis monitored, the internal input voltage after the input i filter is measured. Consequently this voltage differs from the voltage at the connector pins by the voltage drop Δ V across the input filter. ...

Page 17

V ACFAIL signal (VME) Available for units with This option defines an undervoltage monitoring circuit for the input or the input and main output voltage equivalent to option D, and generates the ACFAIL signal (V ...

Page 18

Threshold tolerances and hysteresis monitored, the internal input voltage is measured i after the input filter. Consequently this voltage differs from the voltage at the connector pins by the voltage drop Δ V across input filter and ...

Page 19

Accessories A variety of electrical and mechanical accessories are available including: – Front panels for 19" rack mounting, Schroff and Intermas systems. – Mating H11 connectors with screw, solder, fast-on or press-fit terminals. – Connector retention facilities. – Code key ...

Related keywords