SXN15-48S1V8 Emerson Network Power, SXN15-48S1V8 Datasheet - Page 2

no-image

SXN15-48S1V8

Manufacturer Part Number
SXN15-48S1V8
Description
CONV DC/DC HIEFF 1.8VOUT 15W SMD
Manufacturer
Emerson Network Power
Series
SXN15r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of SXN15-48S1V8

Rohs Status
RoHS non-compliant
Output
1.8V
Number Of Outputs
1
Power (watts)
10W
Mounting Type
Surface Mount
Voltage - Input
33 ~ 75V
Package / Case
11-DIP SMD Module
1st Output
1.8 VDC @ 6A
Size / Dimension
1.91" L x 1.01" W x 0.34" H (48.5mm x 25.7mm x 8.6mm)
Power (watts) - Rated
10.8W
Operating Temperature
-40°C ~ 65°C
Efficiency
83%
Approvals
CE, cUL, TUV, UL
3rd Output
-
2nd Output
-
4th Output
-
SXN15 Series
Notes
1
2
3
4
5
6
7
8
9
10
11
International Safety Standard Approvals
TÜV
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Please consult our website for the following items:
DC/DC CONVERTERS
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
OUTPUT
POWER
(MAX.)
Measured as per recommended set-up. See Application Note 116 for
further details.
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
The SXN15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for further details.
Recommended input fusing is a 2A HRC 200V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with external filter. See Application Note 116 for further details.
Start-up into resistive load.
Active low remote on/off is available. Standard product is active high.
Designate with the Suffix '-R' e.g. SXN15-48S05-R.
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
Signal Line assumed < 3m in length.
This parameter is calculated at worst case line, load, temperature and
initial settings.
10.8W
PIN NUMBER
15W
15W
15W
10
11
1
2
3
4
5
6
7
8
9
UL/cUL 1950 3rd edition. File No. E135734
TÜV Rheinland. Certificate No. R2074133
PIN CONNECTIONS
33-75VDC
33-75VDC
33-75VDC
33-75VDC
VOLTAGE
INPUT
S i n g l e o u t p u t
FEATURE
10.8-15W High Efficiency DC/DC Converters
2.3VDC
3.2VDC
Vout +
On/Off
Vout -
Vin +
4VDC
6VDC
Vin -
Trim
OVP
N/C
N/C
N/C
N/C
N/C
VOLTAGE
OUTPUT
1.8V
2.5V
3.3V
5.0V
BOTTOM VIEW
CURRENT
OUTPUT
TOP VIEW
SIDE VIEW
(MIN.)
Application Note
0A
0A
0A
0A
0.072 (1.83)
1.136 (28.85)
1.483 (37.67)
1.680 (42.67)
0.105 (2.67)
0.302 (7.67)
1
11
CURRENT
1
OUTPUT
10
2
0.110 (2.79)
(MAX.)
4.5A
3
6A
6A
3A
1.905 (48.39)
PROTECTION
Short circuit protection
Overvoltage protection
TELECOM SPECIFICATION
Central office interface A
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
4
9
Longform Data Sheet
0.120 (3.05)
5
8
6
7
EFFICIENCY
0.335 (8.51)
0.840 (21.37)
(TYP.)
0.070 (1.78)
83%
85%
86%
87%
1.010 (25.65)
0.3%
0.3%
0.1%
0.1%
LINE
0.820 (20.83)
0.020 (0.51)
REGULATION
1.020 (25.91)
0.197 (5.00)
All Dimensions in Inches [mm]
File Name: SXN15S.PDF Rev: 16 Oct 2002
Recommended Land & Hole Pattern
ETS300-132-2, input voltage
0.800 (20.32)
LOAD
2.0%
1.5%
0.5%
0.5%
11
www.artesyn.com
1
Tolerance: ± .015 (± .38)
10
1.031 (26.19)
2
and current requirements
3
1.705 (43.31)
Non-latching clamp
0.347 (8.81)
9
4
SXN15-48S1V8
SXN15-48S2V5
SXN15-48S3V3
0.130 (3.30)
SXN15-48S05
NUMBER
8
5
7
6
MODEL
Continuous
0.197 (5.00)
0.110 (2.79)
(8)
2

Related parts for SXN15-48S1V8