PXE3012D12 TDK Corporation, PXE3012D12 Datasheet - Page 2

DC-DC CONVRT +/-12V 30W +/-1.

PXE3012D12

Manufacturer Part Number
PXE3012D12
Description
DC-DC CONVRT +/-12V 30W +/-1.
Manufacturer
TDK Corporation
Series
PXEr
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of PXE3012D12

Output
±12V
Number Of Outputs
2
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
9 ~ 18V
Package / Case
8-DIP Module
1st Output
12 VDC @ 1.25A
2nd Output
-12 VDC @ 1.25A
Size / Dimension
2.00" L x 1.60" W x 0.40" H (50.8mm x 40.6mm x 8.6mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 100°C
Efficiency
87%
Approvals
CE, CSA, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
9V To 18V
Power Rating
30W
Output Voltage
12V
Output Current
1.25A
Output Voltage 2
-12V
Output Current 2
-1.250A
Approval Bodies
UL, CSA, CE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1536
PXE30-12D12

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PXE3012D12
Manufacturer:
TDK-LAMBDA AMERICAS INC
Quantity:
135
Block Diagram
EMI Filter (Optional)
Input filter components (C1, C2, L1) are used to help meet special
conducted emissions requirements for the PXE product. These
components should be mounted as close as possible to the DC-
DC converter; and all leads should be minimized to decrease
radiated noise.
Minimum Load
A 10% (of full load) minimum load is required on each output to
meet the performance specifications. The unit does not maintain
regulation and operate properly under a no-load condition.
Pin Assignments
Pin
1
2
3
4
5
6
7
8
PXE20, PXE30
Connection
+ Input
- Input
No Pin
Remote On / Off
+ Output
Common
- Output
Trim
System Ground
Source
DC
+
-
1µF, MLC
Fuse
C1
C1
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Optional
Filter
EMI
L1
5.5µH
L1
Appropriate hook-up location for
test equipment to monitor output.
C2
+Vin
-Vin
Remote On / Off
220µF 100V
Electrolytic
C2
PXE
Trim
Installation Data Sheet
Com
+Vo
Outline Drawing
Pin Diameter: 1mm (0.04")
-Vo
1. All dimensions in Inches (mm)
2. Pin pitch tolerance ±0.014(0.35)
Bottom
View
8
4
0.40
(1 0.2)
0.70 (1 7.8)
1uf
0.60 (1 5.2)
Load
Load
1 .60 (40.6)
DVM
7
Coax cable
2
1
0.20 (5.1 )
6
0.70 (1 7.8)
0.50
(1 2.7)
0.40
(1 0.2)
0.1uf
5
50Ω
Oscilloscope
0.22 (5.6)
0.40
(1 0.2)

Related parts for PXE3012D12