OKL-T/3-W12N-C Murata Power Solutions Inc, OKL-T/3-W12N-C Datasheet
OKL-T/3-W12N-C
Specifications of OKL-T/3-W12N-C
Available stocks
Related parts for OKL-T/3-W12N-C
OKL-T/3-W12N-C Summary of contents
Page 1
... The OKL-T/3-W12 series are miniature non-iso- lated Point-of-Load (PoL) DC/DC power converters for embedded applications. Featuring inspectable Land Grid Array (iLGA) format, the OKL-T/3-W12 measures only 0.48 x 0.48 x 0.244 inches max. (12.2 x 12.2 x 6.2 mm max.). The wide input range is 4 Volts DC. ...
Page 2
... Input Voltage Range 4.5-14Vdc Maximum Rated Output Current in Amps Model Number OKL-T/3-W12P-C OKL-T/3-W12N-C OKL2-T/3-W12P-C OKL2-T/3-W12N-C The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 10=O and 11 through through Z) Fourth character – ...
Page 3
... The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page OKL2-T/3-W12 9 ,227,000 4,860,000 ...
Page 4
... This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation. www.murata-ps.com 28 Mar 2011 OKL-T/3-W12 Series email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A12 Page ...
Page 5
... Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page Function On/Off Control Ground V OUT Sense Trim Ground No Connection † ...
Page 6
... Pocket tape length before modules C Cover tape length before pocket tape www.murata-ps.com OKL-T/3-W12 Series Programmable Output 3-Amp iLGA SMT PoLs 7.40±0.1 0.40±0.05 Start of pocket tape C B Start of cover tape Length (mm) email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page 800 ±40 200 min. 240 ±40 ...
Page 7
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 5V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=5.0V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 8
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 3.3V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=3.3V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 9
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 2.5V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=2.5V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 10
... Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com 28 Mar 2011 OKL-T/3-W12 Series email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A12 Page ...
Page 11
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 1.2V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=1.2V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 12
... Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com 28 Mar 2011 OKL-T/3-W12 Series email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A12 Page ...
Page 13
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 0.591V Load C urre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=0.591V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=0.591V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 50 mV/div. Trace 4=Iout, 1A/div. ...
Page 14
... The converter will operate with no additional external capacitance if these conditions are met. www.murata-ps.com OKL-T/3-W12 Series email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page ...
Page 15
... CAUTION: These graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. www.murata-ps.com OKL-T/3-W12 Series COPPER STRIP SCOPE C1 C2 COPPER STRIP C1 = 1μF CERAMIC C2 = 10μF CERAMIC LOAD 2-3 INCHES (51-76mm) FROM MODULE email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page LOAD ...
Page 16
... Common HI impedance (Open Drain) = Power Ok LO impedance (Saturation) = Power Not Ok Figure 6. Power Good Circuit www.murata-ps.com 28 Mar 2011 OKL-T/3-W12 Series External +Logic Supply (+5V max.) Power Good 5mA max. User’s External Logic –Vin Logic Ground Power Output email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A12 Page ...
Page 17
... Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max High trace = normal upper limit Preheating Zone Low trace = normal lower limit 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A12 Page 300 ...
Page 18
... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations OKL-T/3-W12 Series © 2011 Murata Power Solutions, Inc. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/3-W12 Series.A12 Page ...