CONV DC/DC 3.3VIN ADJOUT 15A

PTH03010WAD

Manufacturer Part Number
PTH03010WAD
Description
CONV DC/DC 3.3VIN ADJOUT 15A
Manufacturer
Emerson Network Power
Series
PTH03010Wr
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of PTH03010WAD

Output
0.8 ~ 2.5V
Number Of Outputs
1
Power (watts)
37W
Mounting Type
Through Hole
Voltage - Input
2.95 ~ 3.65V
Package / Case
10-DIP Module
1st Output
0.8 ~ 2.5 VDC @ 15A
Size / Dimension
1.37" L x 0.62" W x 0.35" H (34.8mm x 15.7mm x 8.9mm)
Power (watts) - Rated
37.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, cUL, TUV, UL
Output Power
38 W
Input Voltage Range
2.95 V to 3.65 V
Input Voltage (nominal)
3.3 V
Output Voltage (channel 1)
0.8 V to 2.5 V
Output Current (channel 1)
15 A
Package / Case Size
34.8 mm x 15.75 mm x 9 mm
Output Voltage
0.8 V to 2.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
393-1159
N N o o t t e e s s
A
B
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS
SOA curves represent the conditions at which internal components are
within the Artesyn derating guidelines.
Characteristic data has been developed from actual products tested at
25 °C. This data is considered typical data for the converter.
100
90
80
70
60
50
40
90
80
70
60
50
40
30
20
0
0
Vin = 3.3 V, Output Voltage = 2.5 V (See Note A)
1
2
2
Figure 3 - Efficiency vs Load Current
OUTPUT CURRENT (A)
3
Figure 1 - Safe Operating Area
OUTPUT CURRENT (A)
4
4
Vin = 3.3 V (See Note B)
5
6
POLA Non-isolated
6
7
8
8
3 . 3 V i n s i n g l e o u t p u t
PTH03010
9 10 11 12 13 14 15
10
12
14
400 LFM
200 LFM
100 LFM
Nat conv
Vout
2.5V
2.0V
1.8V
1.5V
1.2V
1.0V
GND
Inhibit
V
in
C
(Required)
in
470µF
Track
Margin Down
Margin Up
90
80
70
60
50
40
30
20
0
Vin = 3.3 V, Output Voltage = 1.0 V (See Note A)
+
2
1
2
OUTPUT CURRENT (A)
Figure 4 - Standard Application
Figure 2 - Safe Operating Area
4
R
(Required)
SET
0.5%, 0.1W
6
PTH03010
(Top View)
10
3
8
9
4
File Name: pth03010.pdf Rev (06): 16 Dec 2005
8
5
10
12
NEW Product
C
(Optional)
out
14
330µF
7
6
+
V
o
Sense
Vout
GND
400 LFM
200 LFM
100 LFM
Nat conv
3
L
O
A
D

Related parts for PTH03010WAD