S8VM-10005CD Omron, S8VM-10005CD Datasheet - Page 12

POWER SUPPLY 5V 20A COVERED

S8VM-10005CD

Manufacturer Part Number
S8VM-10005CD
Description
POWER SUPPLY 5V 20A COVERED
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S8VM-10005CD

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
5 VDC @ 20A
Size / Dimension
6.32" L x 1.3" W x 3.25" H (160.5mm x 33mm x 82.5mm)
Power (watts) - Rated
100W
Operating Temperature
-10°C ~ 60°C
Efficiency
81%
Approvals
CE, CSA, cUL, cUR, EN, TUV, UL
Product
Switching
Output Power Rating
100 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Mounting Style
DIN Rail
Dimensions
160.5 mm L x 33 mm W x 82.5 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VM10005CD
Z2487
■ Probable Causes of Power Supply Errors and Troubleshooting Using
Check the following information if the Undervoltage Alarm Function operates.
Contact your OMRON representative if the Power Supply does not function normally after checking.
The symbols in the table are as follows:
Note: Flashing: The output voltage is unstable, causing the LED to repeatedly turn ON and OFF.
12
1
2
3
4
5
6
7
8
: Lit,
Undervoltage Alarm Function
LED D:
DC ON
Green
: Not lit,
Switch Mode Power Supply
LED F:
Yellow
DC LOW1
: Flashing
Transistor
( H to J )
outputs
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
LED G:
Red
DC LOW2
Transistor
( I to J )
outputs
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
S8VM
→ No output
→ Unstable output
Normal
(approx. 90% min.
of rated output
voltage)
Normal
(approx. 90% min.
of rated output
voltage)
Output drop
(approx. 90%
max. of rated
output voltage)
Output drop
(approx. 90%
max. of rated
output voltage)
Output drop
(approx. 80% of
rated output
voltage)
Output drop
(approx. 80% of
rated output
voltage)
Output voltage
Normal status
The output voltage has re-
covered to normal status
following a previous sud-
den voltage drop.
The output voltage has
dropped gradually and re-
mains low.
The output voltage re-
mains low following a pre-
vious sudden voltage
drop.
The output voltage re-
mains low and is continu-
ing to fluctuate following a
previous sudden voltage
drop.
The output voltage has
dropped gradually, re-
mains low, and is continu-
ing to fluctuate.
No output voltage is being
output.
The output voltage is un-
stable.
Power Supply status diagnosis
24 V
24 V
24 V
24 V
24 V
24 V
24 V