VF-D320-D524A-CFS CUI Inc, VF-D320-D524A-CFS Datasheet - Page 2

PWR SUPPLY 320W 5-24V DUAL W/FAN

VF-D320-D524A-CFS

Manufacturer Part Number
VF-D320-D524A-CFS
Description
PWR SUPPLY 320W 5-24V DUAL W/FAN
Manufacturer
CUI Inc
Series
V-Infinity VF-S320r
Datasheet

Specifications of VF-D320-D524A-CFS

Voltage - Output
5V, 24V
Number Of Outputs
2
Power (watts)
320W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 132VAC, 180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 30A
2nd Output
24 VDC @ 8.33A
Size / Dimension
7" L x 4" W x 1.6" H (177.8mm x 101.6mm x 40.6mm)
Power (watts) - Rated
320W
Operating Temperature
0°C ~ 70°C
Efficiency
75%
Approvals
CB, CE, cUL, TUV, UL
Line Regulation
±5%
Load Regulation
±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Other names
102-2009
PART NUMBER: VF-D320-DXXXA-CFS
INPUT
parameter
input frequency
input voltage
Input current
inrush current
power factor
OUTPUT
parameter
transient response
overshoot
efficiency
turn on delay
hold up time
adjustability
LED display
power good
fan drive
PROTECTION CIRCUIT
parameter
input fuse
overload
short circuit
output over-voltage
over temp.
20050 SW 112
th
conditions/description
90-132 / 180-264 auto-selectable
At 100-120 VAC
At 200-240 VAC
Peak measured at 230 VAC at full load, cold start
Peak measured at 115 VAC at full load, cold start
Passive power factor correction meets EN61000-3-2 class A
conditions/description
Output voltage returns to within 1% in less than
2.5 mS for a 50% load change. Peak transient does not exceed 5%.
Turn-on and turn-off overshoot shall not exceed
5% over nominal voltage.
Measured at 230 V and full load
At 120 VAC
At 120 VAC and 80% of rated maximim load
Adjustable with built-in trim pot.
When green (LED1) is on the power supply is operating normally.
Designated as PG on the CN1. This signal
goes TTL high 100-500 mS after the output reaches regulation.
It goes low at least 1 mS before loss of regulation.
12 VDC/400mA for external fan
conditions/description
Built-in ac fuse. A blown fuse usually indicates permanent
damage to the power supply serviceable by factory only.
Current limiting starts at 110-140% of the rated output current in foldback mode and
recovers automatically.
Short circuit can be continuous. Recovers automatically upon removal of short.
Output is protected agaist overvoltage. Unit shuts down and latches
when voltage at output terminals exceeds 130%. AC input needs to be
reset to restart the power supply.
Power supply shuts down when temperature is in excess of 85 ºC. Auto recovery.
Ave. Tualatin, Oregon 97062
phone
phone 503.612.2300 fax
DESCRIPTION: switching power supply
fax 503.612.2383
+/- 5%
75%
min
min
47
90
20
nom
nom
max
max
264
www.v-infinity.com
63
70
35
8
4
1
rev.
page
date
units
Hz
VAC
A
A
A
A
units
second
ms
11/2010
2 of 5

Related parts for VF-D320-D524A-CFS