VMS-365-12 CUI Inc, VMS-365-12 Datasheet
VMS-365-12
Specifications of VMS-365-12
Related parts for VMS-365-12
VMS-365-12 Summary of contents
Page 1
... PFC ·90% typical efficiency ·12 V auxillary fan output ·full medical and ITE safety approvals ·meets the requirements (80+) of the Energy Star 4.0 documents and the anticipated 90+ requirement for 2010 MODEL output voltage VMS-365- VMS-365- VMS-365- ALL 12 V fan aux standby notes: 1 ...
Page 2
... SERIES: VMS-365 RELIABILITY parameter conditions/description MTBF 235K hours min convection, 300K hours typical with 400 LFM forced air (MIL-HDBK-217E-1, 75% of rated full load, 25°C ambient) PROTECTION CIRCUITS parameter conditions/description over current 150% max., auto recovery output over-voltage 125% max. (for 12, 24 short circuit the power supply will auto recover with no damage from a short on any output ...
Page 3
... V While Sinking a maximum Between 2.4 V and 5 V Output While Sourcing 200 µ Pull-Up From +5 Vsb To Termination Point 56 mA for 5µS with a 500 mS on/150 mS off duty cycle V-INFINITY Switching power supply MODEL: VMS-365-12 INPUT: 100-240VAC, 50-60Hz, 5A OUTPUT V1: +12V AT 30.4A V2: +5VDC AT 2A V3: +/-12V AT 1A RoHS C ...
Page 4
... SERIES: VMS-365 MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: open frame switching power supply phone phone 503.612.2300 fax fax 503.612.2383 page 02/2011 date www.v-infinity.com ...