SWS1000L-48 TDK Corporation, SWS1000L-48 Datasheet - Page 2

PWR SUP MED 48V 22A SGL OUTPUT

SWS1000L-48

Manufacturer Part Number
SWS1000L-48
Description
PWR SUP MED 48V 22A SGL OUTPUT
Manufacturer
TDK Corporation
Series
SWS1000Lr
Type
Commercialr
Datasheets

Specifications of SWS1000L-48

Power Supply Type
Switching (Closed Frame)
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
1000W
Applications
Medical
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 22A
Size / Dimension
9.45" L x 5.91" W x 2.4" H (240mm x 150mm x 61mm)
Power (watts) - Rated
1056W
Operating Temperature
-20°C ~ 74°C
Efficiency
86%
Approvals
CSA, DENAN, EN, IEC, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
22A
Power Rating
1056W
Input Voltage
85V AC To 265V AC / 120V DC To 350V DC
Brand/series
SWS Series
Configuration
Enclosed
Output
48 VDC @ 22 A
Power, Output
1056 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 350 VAC/VDC
Voltage, Output
48 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1798
SWS1000L48

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SWS1000L-48
Quantity:
129
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current (115 / 230VAC)
Power Factor
Input Current (100/200VAC)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Parallel Connection
Remote On/Off (CNT)
Voltage Programming
DC Good & Fan Fail Signal
Auxiliary Output
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage(One minute)
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Immunity
Safety Agency Certification
Conducted & Radiated EMI
Weight (Typ)
Size (WxHxD)
Warranty
(1)
Global safety Approvals
Power Factor Corrected
Variable speed fan
Not available on 3.3V & 5V SWS1000L models
MODEL
(1)
mA
ms
yrs
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Output to Ground 500VAC, Output to CNT 100VAC
Input to Ground 2kVAC, Input to Output 3kVAC,
UL, CSA, EN60950-1, UL60601-1 (1000W only), IEC61010-1 (600W only), EN50178, CE Mark
SWS600/1000L
7.1 / 3.6 (3.3V: 5 / 2.5)
-40°C start up. -20 to 74°C, derating linearly to 50% load above 50°C
2.4 x 4.72 x 7.48"
Single Output Low Profile Power Supplies
<0.75mA
SWS600L
1600
>50M at 25C & 70%RH, Output to Ground 500VDC
20 - 90% RH operating, 10 - 95%RH non operating
Yes, 1-6V adjusts output from 20 - 120% of nominal
85 - 265VAC (47 - 63Hz) or 120 - 350VDC
Yes, cycle AC or Remote On/Off to reset
Benefit
LED Signs
Automated Service
EN55011 / EN55022-B, FCC Class B
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
EN61000-4-2, -3, -4, -5, -6, -8, -11
MIL-STD-810F 516.5 Procedure I, VI
Supports Global Use
Supports Global Use
Greater reliability & lower acoustical noise
(2)
Low Cost
Low Profile
Active Power Factor Correction
Universal Input (85 - 265VAC)
Input Transient Protected IEC61000-4
Low Acoustical noise
Medical Certifications (SWS1000L)
MIL-STD-810F 514.5 Cat. 4,10
>105%, Constant current style
Meets EN61000-3-2 Class A
Variable speed internal fan
Yes, open collector output
300uA worse case, 265VAC 63Hz
20ms at 115/230VAC
Green LED = On
-40 to +85°C
125% -145%
<0.02%/°C
Three Years
12V 0.1A
20 / 40
Yes
Yes
Yes
Output to Ground 500VAC, Output to CNT 100VAC
Input to Ground 2kVAC, Input to Output 4kVAC,
Test & Measurement
Medical equipment
100µA at 115VAC 60Hz(2)
2.4 x 5.91 x 9.45"
SWS1000L
12 / 6
2300
83