S8VS-09024 Omron, S8VS-09024 Datasheet - Page 7

PWR SUPPLY W/O DISP 24VDC 3.75A

S8VS-09024

Manufacturer Part Number
S8VS-09024
Description
PWR SUPPLY W/O DISP 24VDC 3.75A
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S8VS-09024

Power Supply Type
Switching (Closed Frame)
Input Voltage
100 VAC to 240 VAC
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
90W
Applications
Commercial
Voltage - Input
85 ~ 264VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 3.75A
Size / Dimension
4.78" L x 1.97" W x 4.53" H (121.3mm x 50mm x 115mm)
Power (watts) - Rated
90W
Operating Temperature
-10°C ~ 60°C
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Output Power Rating
90 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3.75 A
Mounting Style
DIN Rail
Dimensions
121.3 mm L x 50 mm W x 115 mm H
Open Frame/enclosed
Enclosed
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
3.75A
Power Rating
90W
Length
121.3mm
Width
50mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS09024
Z1664
Note: Refer to page 5 for notes 1 to 12.
Item
Efficiency (typical) (rated input voltage)
Input
Output
Additional
functions
Other
Voltage *1
Frequency *1
Current
Power factor
Harmonic current regulation
Leakage current
Inrush current *2
Voltage adjustment range *3
Ripple
Input variation influence
Load variation influence
(rated input voltage)
Temperature variation influence
Startup time *2
Hold time *2
Overload protection *2
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
Maintenance forecast monitor indication *5 No
Maintenance forecast monitor output
Total run time monitor indication *5
Total run time monitor output *5
Undervoltage alarm indication *5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved standards *11
SEMI *11
Weight
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
Conducted
Emissions
Radiated Emissions
Power ratings
Type
80% min.
100 to 240 VAC (allowable range 85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
3.8 A max.
2.0 A max.
0.95 min. (0.9 A max. for BE models)
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
25 A max. (17.5 A max. for BE models)
50 A max. (35 A max. for BE models)
Models with indication monitor (except for BE models): Å}10%
(with V. ADJ)
Standard models (except for BE models): −10% to 15% (with
V.ADJ)
2.0% (p-p) max. (at rated input/output voltage)
0.5% max. (at 85- to 264-VAC input, 100% load)
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
1,000 ms max. (at rated input/output voltage)
20 ms min. (at rated input/output voltage)
105% to 160% of rated load current, inverted L voltage drop, automatic reset
Yes
No
No
No
No
No
No
No
No
No
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in Engineering Data (60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models). (with no icing or
condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard 240-W and 480-W
models: 30 mA, detection current for 240-W models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions: 240 W
10 to 150 Hz, 0.35-mm single amplitude (3 G max.) for 80 min each in X, Y, and Z directions: 480 W
150 m/s
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A and based on FCC Class A, Conforms to
EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B and based on FCC Class A
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A, Conforms to EN61204-3 EN55011 Class B
*11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B
Conforms to EN61204-3 high severity levels
UL: UL508 (Listing), UL60950-1
cUL: CSA C22.2 No.107.1,
cUR: CSA No. 60950-1,
EN/VDE: EN50178 (=VDE0160),
EN60950-1 (=VDE0805 Teil 1) *12
KOSHA S Mark *10
F47-0706 (200-VAC input)
1,150 g max.
Standard
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA
max. *9
forecast monitor
Maintenance
240 W
No
No
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Total run time
monitor
83% min.
7.4 A max.
3.9 A max.
0.95 min.
25 A max.
50 A max.
−10% to 15% (with V.ADJ)
No
No
No
No
No
No
No
Conforms to EN61204-3 EN55011 Class A and based on FCC
Class A
Conforms to EN61204-3 EN55011 Class B *11
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B *11
1,700 g max.
Standard
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max.
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA
max. *9
forecast monitor
Maintenance
480 W
No
No
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Total run time