SWS7515 TDK Corporation, SWS7515 Datasheet

PWR SUP 15V 5A SNG OUTPUT

SWS7515

Manufacturer Part Number
SWS7515
Description
PWR SUP 15V 5A SNG OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Enclosedr
Datasheets

Specifications of SWS7515

Number Of Outputs
1
Efficiency
85%
Voltage - Output
15V
Power (watts)
75W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 5A
Size / Dimension
6.69" L x 3.7" W x 1.69" H (169.9mm x 94mm x 42.9mm)
Power (watts) - Rated
75W
Operating Temperature
-10°C ~ 70°C
Approvals
CE, CSA, EN, UL
Line Regulation
5%
Load Regulation
5%
Output Current (max)
5A
Input Voltage
85 to 265V
Output Voltage
15V
Output Power (max)
75W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Desktop
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1636
SWS75-15
CA730-01-01B
* Read instruction manual carefully , before using the power supply unit.
* 1 : At maximum output power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Please refer to Output Derating Curve for input voltage less than 100VAC (next page).
* 4 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
* 5 : Please refer to Fig A for measurement of line & load regulation, ripple and noise voltage.
* 6 : 85 - 265VAC, constant load.
* 7 : No load - Full load(Maximum power), constant input voltage.
* 8 : Current limiting with automatic recovery.
* 9 : OVP circuit will shutdown output, manual reset (Re power on).
*10: Measured by each measuring method of UL, CSA, EN.
*11: Refer to Output Derating Curve (next page) for details of output derating
10 Line Regulation
11 Load Regulation
12 Temperature Coefficient
13 Over Current Protection
14 Over Voltage Protection
15 Hold-Up Time (Typ)
16 Leakage current
17 Series Operation
18 Operating Temperature
19 Operating Humidity
20 Storage Temperature
21 Storage Humidity
22 Cooling
23 Withstand Voltage
24 Isolation Resistance
25 Vibration
26 Safety
27 EMI
28 Immunity
29 Weight (Typ)
30 Dimension
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Maximum Output Power
Efficiency (Typ)
Input Voltage Range
Input Current (Typ)
Inrush Current (Typ)
Output Voltage Range
Ripple and Noise
Ripple & noise are measured at 20MHz by using a 12'' twisted pair terminated with a 0.1uF and 47uF capacitor.
Avoid to operate at overload or dead short for more than 30seconds.
versus ambient temperature and mounting method .
ITEMS
= NOTES=
(115/230VAC)
(115/230VAC)
(115/230VAC)
(115/230VAC) ( * 1, 5 ) mV
( * 2, 3 )
( * 5, 6 ) mV
( * 5, 7 ) mV
( * 10 )
( * 11 )
MODEL
( * 1 )
( * 1 )
( * 4 )
( * 8 )
( * 9 )
( * 1 )
( * 1 )
( * 1 )
SWS75 SPECIFICATIONS
mm
W
%
V
A
A
V
A
V
g
2.97~3.63
3.79~4.95
SWS75-3
1.1 / 0.7
72 / 68
15.8~
49.5
3.3
15
80
20
40
More than 100M at Ta=25°C and 70%RH, Output - FG : 500VDC
Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA)
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
1mA Max, 0.3mA(Typ) at 115VAC / 0.6mA(Typ) at 230VAC
20A at 115VAC, 40A at 230VAC, Ta=25
Built to meet FCC-Class B, EN55011/EN55022-B
- 10 ~ + 60 °C (Refer to Output Derating Curve)
5.75~6.95
SWS75-5
At no operating, 10 - 55Hz ( sweep for 1min )
4.5~5.5
77 / 74
Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC
15.8~
Output - FG : 500VAC (100mA) for 1min.
43 x 94 x 170 (Refer to Outline Drawing)
15
75
80
20
50
5
19.6m/s
30 ~ 90 %RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
2
Constant, X, Y, Z 1hour each
Convection cooling
Measurement point for Vo Line/Load
Regulation, and ripple and noise.
20ms / 160ms
- 30 ~ +85°C
SWS75-12
10.8~13.2
13.8~16.2
Possible
83 / 81
75.6
6.6~
480
6.3
12
80
48
96
Less than 0.02%/°C
TB1
1.6 / 0.8
+V
-V
SWS75-15
13.5~16.5
17.2~20.3
o
C, Cold Start
85 / 82
5.2~
100
120
5.0
15
75
60
DENSEI-LAMBDA
Fig. A
A
SWS75-24
21.6~26.4
27.6~32.4
85 / 82
76.8
3.4~
100
144
3.2
24
96

Related parts for SWS7515

SWS7515 Summary of contents

Page 1

CA730-01-01B ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Maximum Output Power 4 Efficiency (Typ) (115/230VAC) 5 Input Voltage Range 6 Input Current (Typ) (115/230VAC) 7 Inrush Current (Typ) 8 Output Voltage Range 9 Ripple and Noise (115/230VAC) ...

Page 2

CA730-01-02A SWS75-3,5 OUTPUT DERATING VS Ta CURVE (CONVECTION COOLING) 100 - Ta(°C) MOUNTING A MOUNTING B,C,D Force Air Cooling : Recommended minimum air velocity is 1.2m/s, flow through the component side ...

Related keywords