SCS120PW48 TDK Corporation, SCS120PW48 Datasheet - Page 72
SCS120PW48
Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets
1.SCS120PW48.pdf
(2 pages)
2.SCS120PW48.pdf
(2 pages)
3.SCS120PW48.pdf
(1 pages)
4.SCS120PW48.pdf
(169 pages)
Specifications of SCS120PW48
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
Features and Benefits
Feature
Specifications
ITEMS
Input Voltage range
Inrush Current
Power Factor Harmonics
Regulation Total
Ripple & Noise
Efficiency
Minimum Load
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
DC Good
Remote On/Off (Specify N option)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Isolation
Vibration (non operating)
Shock
Safety Agency Approvals
Immunity
Conducted Emissions and Flicker
Radiated Emissions
Weight (Typ)
Size (without cover)
Warranty
(1) -20°C cold start
(4) Input-Output: Reinforced IEC60950-1, Basic IEC 60601-1.
High Efficiency
Low Profile
Power Factor Corrected
No Minimum Loads
(1)(7)
MODEL
(4)
(2)
(3)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mV
ms
µA
yrs
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-N1 or -N2 option: TTL level high = Off, -N3 or -N4 option: open circuit = Off (except standby)
123µA 120VAC 60Hz, 257µA 240VAC 60Hz, <300µA 264VAC 63Hz (Type Test results)
1%; Including Line (for 90-264VAC input change), Load (for 0-100% load change) and
Conforms to MIL-STD-810E, Method 516.5, Pro I, IV, VI; EN60068-2-6, IEC68-2-6
Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC
Conforms to MIL-STD-810E/F, Method 514.4, Pro I, Cat 1,9; EN60068-2-27,
UL60950-1, CSA22.2 No 60950-1, EN60950-1, IEC60950-1, CE for LVD,
NV175 Series
(2) See application note for Class B
See NV175-M for reinforced medical insulation
Cross (for 0-100% load change on any other output) regulation
0 to +70°C. Derate linearily to 50% load from 50°C to 70°C
EN60068-2-47, IEC68-2-47, IEC68-2-47, JIS C0041-1987
EN61000-6-2:2001, EN61000-4-2, -3, -4, -5, -6, -8, -11
On Outputs CH1 & CH2, 0.5V compensation maximum
90 - 264VAC (47 - 63Hz, 440Hz with reduced PFC)
3” x 5” x 1.25”; N option version 3.7” x 5” x 1.25”
EN55022 Class B (per CISPR.22), EN61000-3-3
UL, EN, IEC60601-1, EN61010-1, IEC61010-1
CH1 & CH2, 120-130%, Cycle AC line to reset
CH1 Only, High on Fail (90% of nominal ±5%)
<40A at 25°C and 264VAC input, Cold Start
EN61000-3-2 Compliant (0.97 typical)
Benefit
Forced air, 2m/s from input to output
3” x 5” 175-200W Power Supplies
Broadcast
Medical
Up to 90%, configuration dependant
Key Market Segments & Applications
1% or 50mV (Which ever is greater)
Less heat dissipated in system
Fits in 1U enclosures
Supports Global Use
Ease of Use
EN55022 Class A (per CISPR.22)
1-5 Outputs
Up to 90% Efficient
Active Power Factor Correction
Universal Input (90 - 264VAC)
No Minimum Loads
Medical Approvals (Basic Insulation Input-Output)
>16ms at 90VAC Input
-40 to +85°C
5 - 95% RH
Three Years
>105%
NV175
None
250g
Yes
Test & Measurement
Industrial Computing and Routers
(3) Including underside component leads
71